Compressive Strength of Masonry Prisms
Many factors affect the estimation of compressive capacity of a masonry prism. In the study the effects due to grout strength, mortar joints, block geometry and size, moisture content,...
Cyclic Behavior of Joints Between Steel Beams and Reinforced Concrete Columns
The design and behavior of composite beam-column joints for seismic design are reviewed based on the results of tests. Issues addressed include the strength, deformation, and toughness...
Rigid Beam-To-Column Connection Detail for Circular Composite Columns
Steel pipes with relatively thin wall thickness and filled with high strength concrete have been used in building construction. Some of the advantages of this type of column include eliminating...
Seismic Response and Retrofitting of Non-Ductile Reinforced Concrete Bridges
The Interstate I5/I605 Separator in Los Angeles County was severely damaged during the October, 1 1987 Whittier Narrows Earthquake. This damage included non-ductile shear failure in the...
Testing of Concrete Curtain Wall Panels Reinforced with FRP Grids
The objective of this paper is to evaluate the suitability of Fiber Reinforced Plastic (FRP) grids for use as a structural; reinforcement in concrete curtain wall panels. This paper describes...
Development of Hardwood Glulam Timber Bridge Standards
Design standards and specification for 5.5 to 27.4 m(18 to 90 ft.) clear span hardwood glued laminated (glulam) highway bridges have been developed and are available from the Pennsylvania...
Laser Generation and Detection of Ultrasound in Concrete
Laser ultrasonics is a non-contact nondestructive evaluation method that uses lasers to generate and detect elastic waves. In this work, laser ultrasonics is used to produce broadband...
Prediction of Structural Response to Large Earthquakes by Using Recordings From Smaller Earthquakes
The feasibility of predicting structural response to large earthquakes by using recorded responses from collocated smaller earthquakes is investigated. Records from large earthquakes can...
Long-Term Monitoring of Civil Structures using Smart Structures Techniques
A smart monitoring program for a hybrid concrete-steel building in Washington, D.C. has been developed. The building is currently being instrumented with a variety of strain and corrosion...
Design and Construction of Post-Tensioned Concrete Floor Systems
This is a summary of the original full length paper which is available from the author. This paper assumes a basic technical knowledge of reinforced concrete design and prestressed concrete...
Nonlinear Analysis of Prestressed Concrete Structures
This paper presents a finite element model for the nonlinear analysis of prestressed concrete structures. The model can be used to analyze pretensioned or posttensioned, bonded or unbonded...
Recent Advances in 3D Non-Linear FE-Analysis of R/C and P/C Beam Structures
A new simple modelling of interface problems in non-linear FE-analysis of reinforced concrete (R/C) and prestressed concrete (P/ C) structures is presented. It consists in taking account...
Prestressed Concrete Failures Due to Uplift
The paper presents some examples of prestressed concrete DOUBLE-TEE (DT) failures caused by hurricane Andrew. The DT's failures was mainly due to the negative moment created by uplift....
A Probabilistic Approach to the Response of Tall Buildings to Wind Loadings
Tall buildings constructed in recent years are light in weight, flexible and low in damping. This is the consequence of using lighter material with higher strength, and fewer interior...
Seismic Response of Concrete Tilt-Up Systems
A Summary of the measured dynamic response of a one-story, till-up warehouse located in Hillister, California, is presented. Acceleration and relative displacement histories may be used...
Cyclic Performance of Riveted Connections
As part of a larger experimental project on seismic performance of older steel frames, seven concrete-encased and unencased connections were tested. The specimens consisted of both riveted...
Seismic Behavior of Non-Ductile Concrete Frame Structures
Non-ductile reinforced concrete (RC) frame structures designed and constructed during the 1950's through 1970's exist in many regions of the United States. The frames of these structures...
Seismic Retrofit of R/C Columns with Inadequate Lap Splices
This paper presents experimental results on the use of rectangular steel jackets to improve the seismic performance of rectangular steel jackets to improve the seismic performance of rectangular...
Compressive Strength of Large Scale HSLA-80 Steel Cellular Sections of a Double Hull Ship Structure
An analytical and experimental large scale test program was conducted to investigate the instability failure modes of cellular double hull box sections. The main emphasis of the study...
Design and Analysis of the 712 Fifth Avenue Structure
New York City's 712 Fifth Avenue is an extremely-slender concrete tube tower. This text addresses the structure's lateral structural system, wind analysis, computer model, thermal analysis...
Return to search