Structural Consequences of Imperfection in Thin-Walled Components

Forensic Evaluation of Guyed Tower Collapses

Seismic Analysis of Concrete Towers of the San Diego–Coronado Bridge and Evaluation of a High Performance Concrete Retrofit

Collapse Analysis of a 190 M Guyed Mast

Test Experience with Heavy Angle Dead End Lattice Transmission Towers
During the past three years, the Electric Power Research Institute's Transmission Line Mechanical Research Center has conducted full scale tests on three 500kV heavy angle dead end lattice...

Assessment and Upgrade of an Older Transmission Line
This paper discusses the various tools and procedures which have been used to assess and upgrade an older 130 kv tower line. The purpose of the assessment was to determine the line compliance...

ASCE GUIDE for Design of Guyed Transmission Structures
This paper describes the contents of a new ASCE guide for the selection and design of guyed electrical transmission structures. Guyed transmission structures present unique analysis and...

Construction of the Baytown Bridge, Houston
Connecting Baytown and LaPorte, the Baytown Bridge is a twin structure with four traffic lanes each. Its structure is designed as a cable-stayed bridge with concrete towers and composite...

Ultimate Strength of R/C Cooling Tower Shell
Reinforced concrete(R/C) cooling towers are the largest, thin shell structures. It is important to assess the ultimate strength of R/C cooling tower shells subjected to wind load. In the...

Repair of a Cracked Cooling Tower Shell Based on Numerical Simulations
The present condition of a 30 years old cooling tower shell made of reinforced concrete is characterized by a relatively large number of long, thermally induced meridional cracks. For...

Transient Response of Guyed Telecommunication Towers Subjected to Cable Ice-Shedding
This paper presents the results of a numerical study of the transient response of guyed telecommunication towers subjected to sudden ice shedding from the guy wires. Detailed nonlinear...

Akashi-Kaikyo Bridge Underconstruction
This paper presents 1) brief history of the survey work, 2) brief description of the physical dimensions and structural system, 3) major studies for the design, 4) development of higher...

Seismic Behaviour of Tall Guyed Telecommunication Towers
This paper presents results of a detailed numerical modelling study of two guyed telecommunication towers subjected to seismic excitation: a 107-m (350 ft) tower with six stay levels,...

Aeroelastic Study of Long Span Suspension Bridges: the Messina Crossing
This paper deals with wind actions on long-span suspension bridges. Particular reference is made to the Messina Strait Crossing. Problems encountered in this study, both for deck and towers,...

Reliability-Based Design of Transmission Towers Under Wind and Ice Loadings
This study suggests a practical but rational approach for the development of reliability-based LRFD criteria for transmission towers under wind and ice loadings in Korea. Based on available...

Buckling of Guyed Towers
The buckling load of a column guyed in a plane by symmetric guy wires is considered. The column is built-in at the ground, supported at the top by guy wires, and is loaded by a vertical...

Research of the Limit Function About Imperfection and the Approximately Calculating Method of the Internal Forces of Hyperbolic Cooling Tower
The authors use the finite elemental program, which made by themselves and makes use of finite element method with rotational shell, to calculate the deformation in hyperbolic cooling...

Computer-Aided Guyed Tower Analysis for the Rehabilitation of TTI Tower, Baltimore
A large guyed television tower owned by Television Tower Inc. of Baltimore is currently being analyzed in order to evaluate the capacity of the tower to support additional broadcasting...

Superlong Cable-Stayed Bridges
Superlong cable-stayed bridge span is defined as one over 1000 meters. Problems requiring special attention regarding these bridges are discussed, namely: excessive cable sag; high axial...

Nutrient Removal for Two Industrial Recycling Projects

 

 

 

 