Two Full-Scale Tests of Class 3 Composite Beams
This paper presents two tests of continuous composite beams comprising two 7.5 m spans and two concentrated loads close to the intermediate support. Although the cross-sections on the...

Modern Design Concept for Composite Slabs with Ductile Behaviour
Numerous tests with different types of composite slabs have been carried out in the laboratory for constructional engineering of the University of Kaiserslautern, Germany in order to determine...

Slim-Floor Beams: Design Criteria and Structural Behaviour
Partially concrete-encased steel beams are mostly employed due to their natural resistance to fire, but there may also be other reasons, e.g. to obtain smaller depths of construction....

Thermal Shielding in Continuous Span Composite Slabs
The increasing popularity in Europe of composite slabs with cold-formed steel decking has underscored the need to improve calculation rules for the fire resistance. Existing rules have...

A Simple Finnish Method for the Structural Fire Design of Composite Structures
The structural fire design of composite structures in Finland has previously been based on furnace tests, which are expensive and take too much time to arrange. With the increasing prominence...

Comparison of Simple Calculation Methods for the Fire Design of Composite Columns and Beams
There is a need for approximate calculation methods to do the fire design of composite structures. Several of such methods for composite beams and columns have been compared to find out...

Seismic Performance and Composite Action of Older Structures
A study into the seismic performance of older steel structures is described. A review is made of the types of steel building construction completed during the period of interest, and the...

Force Transfer in Composite Columns
The force transfer from steel to concrete without mechanical transfer devices in composite columns at points of load introduction is studied. A mechanism of force transfer and the factors...

Steel Panel Encased R.C. Composite Shear Walls
In order to make clear the fundamental resisting mechanisms of composite shear walls, tests are carried out on the composite unit rigid frames with various infilled shear walls. Composite...

Chemical Resistance of Thermosetting Resins Used for Cured-in-Place Pipe
This paper summarizes the chemistry, short term physical properties, and long term chemical resistance for representative epoxy vinyl ester, epoxy, and polyester resins that are currently...

The Design and Development of A Road/Rail Power Unit
The road/rail power unit was designed and developed by Saskatchewan Highways and Transportation to provide low cost motive power on low-density disconnected rail lines. The power unit...

Modification of Beech Dam for Seepage Control and Upgrade for the Maximum Credible Earthquake

Re-powering Nine Mile Hydroelectric Project

Unit 1 and 2 Rehabilitation at Crescent and Vischer Ferry

Seneca Pump Turbine Rehabilitation Pennsylvania Electric Company/GPU Cleveland Electric Illuminating Company

Hydro Task Force Evaluations Northern States Power Company

Switchgear Fault, Damage Control, Recovery and Redesign at the John Day Powerhouse

Air Blast Circuit Breaker Replacement Arc Chutes

Variable Speed Power Conversion Technology for Hydro Applications Under 10 MW

Plant and System Benefits Associated with Adjustable Speed Hydro

 

 

 

 