The Effective Use of Fire Ratings
Any consideration of components for construction must take into account the performance of those components when they are exposed to fire. Codes, standards, and fire ratings provide some...
A California Tower: Response to Seismic Forces
First Interstate World Center is a signature building for the city of Los Angeles. The granite clad tower with its serrated facade rises 1,018 ft. above street level. It is the tallest...
Structural Design and Wind Resistance of Fukuoka Tower with T.M.D.
Fukuoka Tower, which was built in 1989, was projected as a monument, a observation tower and a broadcasting antenna with 234m high. In this tower, a Tuned Mass Damper(TMD) was set, in...
Long-Span Design for Seismic Forces—A Case Study of the Anaheim Arena
The design for the Anaheim Arena roof evolved in response to the strict requirements for a structure in a seismic zone 4 location. The support of the 329 ft. (100 m) by 444 ft. (135 m)...
Structural Response Using Stiffness Decoupler
The structural properties of a new stiffness decoupler developed by Hu, Kirmser and Swartz at Kansas State University, and its applications as an energy absorber and a device to isolate...
Steel Plate Energy Absorbers for Improved Earthquake Resistance
This paper discusses results of an combined experimental and analytical investigation on seismic response of frame structures using welded steel triangular plates as added damping and...
Robust Control for Buildings Under Earthquake
Robust control techniques are applied to civil engineering structures subjected to earthquake excitation. Full state feedback and observer based control laws are used to reduce the response...
Passive Energy Dissipation Systems for Earthquake-Resistant Design
Passive energy dissipation devices, also known as supplemental damping devices, have been proposed as a means by which the earthquake resistance of a building can be substantially enhanced,...
Fluid Viscous Damper for Improving the Earthquake Resistance of Buildings
Experimental results are presented which demonstrate that the use of fluid dampers as add-on devices in moment resisting frames substantially increases damping and reduces seismic story...
Viscoelastic Dampers for Seismic Pounding Mitigation
A hysteretic model for viscoelastic (VE) damper is explained. The model accurately accounts for the effects of excitation frequency as well as temperature of the damper. Benefit of using...
Recent Developments in Seismic Isolation Technology
Large experimental research projects for isolators for both civil structures and nuclear reactor applications have been conducted at the Earthquake Engineering Research Center (EERC) over...
Evaluation of Seismic Isolation Schemes for a Historic Building
The U.S. Court of Appeals Ninth District building originally completed in 1905 with an expansion in 1933, suffered damage during the 1989 Loma Prieta earthquake. The building is currently...
Seismic Strengthening for Structures in Regions of Low Seismicity
Most existing structures were not designed to today's seismic codes and standards, and in fact in low seismicity regions codes did not require seismic design until recently....
Developing a New Construction Policy for Bridge Management
The SHRP Program and other rehabilitation strategies are based on extending the life of concrete bridge elements. In the Bridge Inventory are a number of bridges that must be reconstructed....
Development of Bridge Load Model for LRFD Code
The load models are based on the available statistical data on dead load, truck loads and dynamic loads. The paper deals mostly with the static live load. The model is derived from truck...
Reliability-Based Design of Transmission Towers Under Wind and Ice Loadings
This study suggests a practical but rational approach for the development of reliability-based LRFD criteria for transmission towers under wind and ice loadings in Korea. Based on available...
Damage Estimation of Existing Bridge Structures
During recent earthquakes, severe damage have been reported in many bridge structures. Regardless of many damaged structures, methods to identify damage of structures are still limited...
A Reduced Order Model for the Seismic Analysis of Building-Soil Systems
A finite element based, reduced order, numerical model has been developed for the nonlinear analysis of building-soil systems. The reduced order system model employs an equivalent continuum...
Development of an Improved Rapid Seismic Analysis Procedure
New developments in computer capabilities and lessons learned from recent earthquakes have facilitated improvement of the Rapid Seismic Analysis Procedure (RSAP) currently specified in...
Analysis of Masonry Walls with Smeared and Discrete Crack Models
To design modern reinforced masonry structures for seismic loads and to evaluate the seismic safety of existing unreinforced masonry buildings, the shear resistance of masonry shear walls...