Evaluation of Code Accidental-Torsion Provisions Using Earthquake Records from Buildings
Building code provisions for accidental torsion are evaluated from analysis of earthquake-induced motions of three nominally-symmetric-plan buildings. The results demonstrate that the...
Building Separation Rules to Avoid Seismic Pounding
A method to estimate the required separation to preclude pounding between adjacent buildings is presented. It accounts for the effect of yielding on the vibration phase of adjacent buildings....
Displacement Amplification Factor for Seismic Design Provisions
To estimate the maximum roof and story drifts occurring during severe earthquakes, the UBC and NEHRP use 3Rw/8 and Cd...
Evaluation of US Seismic Code Provisions for Asymmetric-Plan Systems
The effects of plan asymmetry on the earthquake response of code-designed, one-story systems are identified with the objective of evaluating how well these effects are represented by torsional...
Earthquake Resistant Design and Construction of Reinforced Concrete Buildings. The Practice in Mexico After 1985
The evolution of the design and construction practice of reinforced concrete buildings in Mexico is presented in terms of materials, structural systems, member design and reinforcement...
Techniques for Seismic Rehabilitation of Buildings in Mexico City
The 1985 earthquake in Mexico City caused collapse or damage of a large number of engineered buildings. After this event several hundreds of buildings were retrofitted using several techniques....
Response of Knee-Brace-Frame Under Seismic Loading
Recently a new framing system called the Knee-Brace-Frame (KBF) has been proposed for seismic resisting structures to overcome the deficiencies of moment resisting frame and concentrically...
Seismic Upgrade Design of Buildings
Building owners and users in seismically prone areas are becoming increasingly aware of the potential risks associated with the seismically hazardous buildings in the region specially...
Effect of First-Story Shearwalls on Earthquake-Resistant Buildings
A Practical system for earthquake-resistant building design is described. The system utilizes Teflon sliders at the top of the first story framed shearwalls to carry a portion of the superstructure....
Welded Wire Confinement Grids
The invention of a new way to reinforce concrete using high strength welded wire grids, (WWG) increases its earthquake resistance by improved ductility and also opens the way for vast...
Earthquake Strengthening of a Twelve Story Non-Ductile Concrete Frame Building with Unreinforced Masonry Using Displacement Control Criterion
The structural concern with the Cooper Arms Apartment building when subjected to ground shaking was the in-plane and out-of-plane forces on the infill and consequences of the infill resisting...
Report and Summary of ATC-31—Evaluation of the Performance of Seismically Retrofitted Buildings
Structural and damage data for seismically retrofitted buildings affected by the October 1, 1987 Whittier Narrows and October 17, 1989 Loma Prieta, California earthquakes were collected...
Tension Pile Test
The California Department of Transportation is conducting FULL SCALE AXIAL LOAD TESTS of 34 piles. This research project/proof test is being jointly conducted by public agencies (Caltrans...
San Francisco Bayshore Viaduct Seismic Retrofit
The Bayshore Freeway viaduct is located in the city of San Francisco and serves as a vital transportation link between the Bay Bridge and points south along Highway 101. This structure...
Link Length Design and EBF Seismic Performance
Twenty eccentrically braced frames (EBFs) are designed using the current seismic design code and newly developed step-by-step design procedure. The EBFs have a variety of link lengths...
Connectors for Earthquake Resistant Structures
Damage assessments from the past several earthquakes located on the northern, central and southern zones of the San Andreas Fault - Cape Mendocino: April 1992, 7.1; Loma Prieta: October...
The European Approach to Seismic Design of Engineered Timber Constructions: The Case of Low-Dissipative Structures
In the present paper the importance of the dissipated energy on the actual structural behaviour of low-dissipative structures as glulam portal frames with mechanical fasteners under seismic...
Fire Endurance Model for a Metal-Plate-Connected Wood Truss
A numerical model has been developed for predicting the fire endurance of a single metal-plate-connected wood truss. Extensive component fire testing was conducted to develop the necessary...
Full Model Wind Tunnel Tests for the Akashi Kaikyo Bridge
In order to carry out final verification of the wind resistance safety of the Akashi Kaikyo Bridge under construction, which has the largest main span of 1,990 m, its full aeroelastic...
Design Wind Speed and Design Criteria of Buildings
Design load recommendations of Architectural Institute of Japan(A.I.J.) are revised according to a common principle to all kinds of loads. The basic wind speed is defined as the annual...
Return to search