Earthquake Resistant Design and Construction of Reinforced Concrete Buildings. The Practice in Mexico After 1985
The evolution of the design and construction practice of reinforced concrete buildings in Mexico is presented in terms of materials, structural systems, member design and reinforcement...
Seismic Strengthening of R/C Columns Using Steel Jackets
This paper presents experimental results on the use of steel collars and steel jackets as a retrofitting system to improve the seismic performance of short rectangular reinforced concrete...
Use of Eccentric Steel Bracing for Strengthening of R/C Frames
This paper presents preliminary results of ongoing research investigating the feasibility of steel eccentrically braced frames (EBFs) for seismic retrofit of reinforced concrete frames....
Code Provisions for Unreinforced Masonry Bearing Wall Buildings in California
Prior to the Long Beach earthquake of 1933, unreinforced masonry (URM) construction was usual in California, as it still is in many areas of the United States. The poor performance of...
CenterCore Strengthening System for Seismic Hazard Reduction of Unreinforced Masonry Bearing Wall Buildings
The CenterCore technique of reinforcing unreinforced masonry walls was developed with the help of a National Science Foundation grant in 1984. The CenterCore strengthening system consists...
Seismic Behavior of Weak-Column Strong-Beam Frames
An experimental evaluation of the seismic performance of moment-resisting steel frames using Weak-Column Strong-Beam joints is described. A simulated seismic response is imposed on five...
Cyclic Behavior and Seismic Design of Steel Base Plates
The objectives of this study were to conduct realistic experiments to understand cyclic behavior of steel column base plates and to develop seismic design recommendations. Six specimens...
A Comparison of the Cyclic Performance of Bolted and Riveted Connections
As part of a larger project to investigate the performance of older steel frames, a comparative study of bolted and riveted T-stub connections was conducted. The study included connections...
Some Unresolved Issues in Seismic Steel Codes
In the latest revisions of the three major U.S. seismic codes (AISC, NEHRP, UBC) some requirements can be questioned because of limited knowledge. Confining attention to conventional kinds...
A General Hysteresis Model for Wood Structures
To predict the dynamic response of a wood structure, its energy dissipation mechanism and hysteresis behavior must be appropriately modeled. This paper presents a new hysteresis model...
Fire Retardant Treated Wood
The paper explains how FRTW chemicals react with combustible gases. It describes the two types into which FRTW is divided. Misconceptions about FRTW are also addressed....
Fire Endurance Model for a Metal-Plate-Connected Wood Truss
A numerical model has been developed for predicting the fire endurance of a single metal-plate-connected wood truss. Extensive component fire testing was conducted to develop the necessary...
A Wind Tunnel Study of an Aeroelastic Model of the Florida Suncoast Dome
Very large scale cable domes have been built using prestressed, high strength steel cable or strand, steel tube columns and a lightweight fiberglass skin. Geiger Engineers Florida Suncoast...
The Effective Use of Fire Ratings
Any consideration of components for construction must take into account the performance of those components when they are exposed to fire. Codes, standards, and fire ratings provide some...
Things That Fall?Lessons from Some Construction Accidents and Structural Failures
The causes and results of several construction accidents are reviewed. The lessons to be learned from such a summary are that all too often the simplest oversight leads to catastrophic...
Tuned Mass Damper in Tall Building Design
Viscoelastic dN and tuned mass dampers are often used by tall building designers to control wind-induced building vibrations resulting from such phenomena as vortex shedding, galloping,...
Vortex Shedding Induced Fatigue Fracture of Mast Tower
The fracture of a pair of 60m high circular steel masts is investigated. The design criteria and fabrication practices are reviewed. The cause of failure is related to the fatigued condition...
85 Stories in Kuala Lumpur?The 5th and 6th Tallest Buildings in the World
A concrete core and cylindrical concrete tube structure provides a safe, elegant, efficient and constructible solution to the challenge of designing the world's 5th and 6th tallest buildings,...
Steel Plate Energy Absorbers for Improved Earthquake Resistance
This paper discusses results of an combined experimental and analytical investigation on seismic response of frame structures using welded steel triangular plates as added damping and...
Response of Equipment in Structures Supported on Resilient-Friction Base Isolators Subjected to Ground Motion
In this paper, the response of equipment in structures on a particular friction-type device, the resilient-friction base isolator, is examined. The R-FBI is composed of layers of Teflon...
Return to search