Six Story Tubular Atrium
The author designed an atrium structure with two stair-stepped atriums placed at 45? to the tower 'Figueroa at Wilshire' in Los Angeles, California. This structure...
Toronto Skydome Retractable Roof Stadium?The Roof Concept and Design
The Toronto SkyDome is a first of its kind sports stadium with a retractable roof which results in, essentially, a fully open air stadium with the roof fully retracted. This unique roof,...
The Fabrication and Erection of the Minneapolis Convention Center
A new convention center is part of the City of Minneapolis' successful plan to maintain an economically strong downtown core. It is the latest addition to a list of civic...
Changes in Tubular Design Codes
This paper summarizes a number of changes in design provisions for tubular structures that have recently been adopted. These are the result of a number of research advances concerning...
Effective Length Factors for Type-PR Frame Members
The effects of PR-Type connections and loading arrangement on frame stability and the effective length factor of columns are evaluated for portal frames and three-story three-bay frames...
Buckling Design of Vierendeel Reticular Shells
Double layer reticular shell structures carry very little transverse shear, thus, it may be appropriate to substitute the inter-layer diagonal members with 'space'...
Behavior of Plates Under Partial Edge Loading
This paper addresses one of the common problems in designing thin-walled members, the ability of the shape to accommodate in-plane concentrated loads. Specific areas in which the problem...
Stability of Plates Under Eccentric Edge Loads
A linear finite element analysis was conducted to study the stress distribution in the web and the flange when the beam is subjected to a patch load applied in the plane of the web or...
Local Buckling Behavior of Plate Elements
In the elastic post-local buckling range, the stress distribution across the width of compression elements of light gauge steel shapes is nonlinear. For code implementations, these stress...
New Concepts in Transmission Line Design
Committees of the American Society of Civil Engineers have been in the forefront on updating design guides to address improved procedures for conventional latticed towers, formed-plate...
Longitudinal Impact Loading of Transmission Towers
A scale model has been developed to study a containment failure design concept for longitudinal (along the direction of the conductor) impact loading of electrical transmission structures....
Limit State Analysis Correlated to a Full Scale Tower Test
A Limit State analysis technique has been developed for evaluating the structural capacity of lattice steel electrical transmission towers. The tower strength is determined by using a...
Variation in Design Practice for Lattice Towers
The design and analysis procedures employed for lattice transmission towers vary among countries, companies, and designers. This variation in design practice affects the relative reliability...
New Outlines for 500 kV Transmission Towers Using Cold-Formed Shapes: The Experimental Line of the American Electric Power Research Institute
The use of cold-formed steel members, in electrical transmission towers, is actually a feasible, reliable and economical solution. The EPRI experimental line is an example of the newest...
Modular Restoration Structures?A Versatile and Cost Effective Transmission Tool
Most electric utilities use a large variety of different types and designs of transmission structures. Because of this, it is not practical or economically justifiable for these utilities...
Sizing Techniques for Lateral Bracing
Techniques for determining the size of lateral bracing members in multi-story steel buildings are presented and discussed. Because the design of such bracing is usually controlled by deflection...
The Design of Diagonal Cross-Bracing
The results of an analytical and experimental study on the behavior of simple and double diagonal cross-bracings in vertical stiffening trusses and in built-up open web beams are presented...
Brace Behavior in a Structural Steel Seismic Retrofitting Scheme
A two thirds scale non-ductile reinforced concrete frame strengthened by an external structural steel bracing scheme was constructed and tested in the laboratory. The frame was subjected...
Double Angle Bracing Members
It has been pointed out that when a single line of bracing is used, the member is usually made from structural tubing. It has been suggested that when the loads are not too great, consideration...
Seismic Behavior of Built-Up Bracing Members
The influence of stitch design and local buckling on the seismic behavior of welded bracing members made of double angles is studied in this paper. Performance of boxed configuration with...