Load Tests on Bored Friction Piles in Clay
For the first time in Boston, Massachusetts, U.S.A., uncased bored friction piles in clay were used to support a six-story residential structure over a 60- to 75-foot (1.83 to 22.9 m)...
Skin Friction Load Test for Caissons in Residual Soils
Results of a load test on a drilled pier are presented. The test was performed to measure only skin friction of a 36 inch (0.91 m) diameter shaft without support at the end. The load test...
Full Scale Caisson Load Test for the Milwaukee Center
Top-down procedures were proposed to construct four basement levels for a major high-rise building development in Milwaukee, Wisconsin. Drilled caisson foundations were the preferred means...
Drilled Shafts?A Database Approach
A database of 43 drilled shaft load tests of high quality has been developed to study parameters that affect the axial behavior of drilled shafts and methods of analysis to predict axial...
Interpretation of Load Tests and Drilled Shafts?Part 3: Lateral and Moment
Existing interpretation methods for lateral and moment load tests are reviewed critically, and a qualitative and quantitative comparison is made for selected methods. A new method is proposed...
Nondestructive Testing of Deep Foundations with Sonic Methods
Nondestructive testing and evaluation (NDT&E) of deep foundations with three sonic methods is discussed. Case history investigations described include test records from drilled...
Geophysical and Nuclear Methods for Non-Destructive Evaluation of Caissons
Non-destructive testing techniques were used to confirm the concrete integrity on the caisson foundations for the 45-story Ohio Corporate Headquarters building in Cleveland, Ohio. The...
Performance of a Large Ribbed Mat on Cohesive Soil
The performance of a 678-ft by 304-ft (207-m by 93-m) ribbed concrete mat was studied to provide improved soil input parameters for design. The mat was constructed on a low plasticity...
Interpretation of Instrumented Driven Steel Pipe Piles
This paper presents the results of a series of studies on the behavior of driven close-ended steel pipe piles. Extensive field explorations and geotechnical analyses have been carried...
Pile-Drilled Caisson Combination for Foundation of High Rise Building
The analysis and evaluation of several alternatives for foundations of a high rise office building is presented, which resulted in the selection of a combination of high capacity piles...
Cost Effective Pile Foundation Supports Fast Track Paper Mill
This paper decribes the generalized subsurface conditions, pile evaluation and load test program, pile and piling contractor selection, production pile installation, and quality assurance...
Evaluation of a 50-Year Old Barge Dock on the Missouri River
The installation of a large crane on an existing barge dock on the Missouri River in Kansas City, Kansas required an evaluation of the dock system stability. The dock was constructed of...
Combination Drilled Shaft and Driven Pile Foundation for a High-Rise Building
A case history is presented which discusses the design and construction of a combination drilled shaft and driven pile foundation which supports a high-rise in San Francisco. Drilled piers,...
Performance of a Building Foundation Designed to Accommodate Large Settlements
The Eastern Airlines shuttle terminal at LaGuardia Airport in New York City is supported on spread footings founded in an incinerated refuse fill which overlies a deep deposit of slightly...
Special Bedrock Conditions and a Foundation Project in Greater Boston
In the greater Boston area the argillite bedrock and/or the overlying glacial till provide suitable support for a wide range of foundation systems, including high capacity end-bearing...
Long Term Performance of High Rise Mat Foundation
The vertical movement of the foundation soils for a multi-story high rise office tower was monitored during foundation excavation, tower construction and the 25-year in-service period...
Complex High-Rise Foundation Design and Construction
The substructure design and construction of a 60 story office tower in downtown Chicago is described. The presence of existing belled caissons on hardpan required use of filtered dewatering...
Sensitivity Study of the Cyclic Axial Capacity of a Single Pile
Evaluation of the axial capacity of an offshore pile subjected to a severe North Sea storm is presented. Effects of using different degradation criteria, upper and lower bound interaction...
Design, Construction, and Load Testing of a High Capacity Caisson
This paper describes the large diameter caisson foundation for the upstream guidewall at the Lock and Dam No. 26 (Replacement) Project. The guidewall is supported on two rows of 6-foot...
Axial Capacity of Pressure-Injected Piles: A Cavity Expansion Model
The application of cavity expansion theory to the development of a mathematical model for predicting the ultimate axial capacity of pressure-injected piles in cohesionless soils is presented....
Return to search