Statistical Properties of Prestressed Concrete Beams in Shear
Monte Carlo simulations were performed on prestressed concrete rectangular and tee-section beams in shear produced by a single concentrated load at mid span. The truss analogy model was...
Strategies for Bridge Inspection Using Probabilistic Models
This paper describes the application of probability analyses in planning an inspection program for highway bridges. When damage in the form of fracture and cracking is the major concern,...
Reliability Assessment and Reliability-Based Rating of Existing Road Bridges
A practical reliability model for the safety assessment and rating of existing R.C. bridges are developed by explicitly incorporating the degree of deterioration and damages based on available...
Vibration Tests and Damage Detection of P/C Bridges
A three-span countryside P/C bridge has been found to have excessive deflections in two of the three spans. It is reported that the prestresses in tendons of two girders of different spans...
The Prefab Tunnel
Jacking a prefabricated concrete arch through a railroad embankment to provide a new access ramp to the Don Valley Parkway in Toronto was done for the first time in North America. In September...
Tales From Milwaukee's Underground
Written from RETC papers and interviews, this article is a status update on the Milwaukee Metropolitan Sewerage District's $2.1 billion Water Pollution Abatement program,...
Downtown in Soft Ground
Critchfield and MacDonald describe the shield excavation of twin bus tunnels 21.25 ft in diameter and 5,000 ft long as part of the Downtown Seattle Transit Project. This $450 million project,...
Prestressed Concrete Pipe Field Test
Strain changes in the prestressing wires and deflections of a 2130-mm-diameter precast (embedded cylinder), prestressed concrete pipe were measured during earth backfilling operations....
Buried Structural Capacity of Insituform?
In July 1988, a test was conducted at Utah State University to determine the structural support that can be provided to a failing rigid pipe system through the use of the Insituform process....
Investigation & Rehabilitation of Seattle's Tolt Pipeline
Seattle Water Department's Tolt Pipeline brings water 24 miles from storage in the Cascade Mountains into city and suburban distribution systems. Twenty-three miles of this...
In-Situ Evaluation of 30-In. (762-mm) Diameter Prestressed Concrete Lined-Cylinder Pipeline
The results of an extensive investigation to evaluate the in-service condition and future serviceability of an existing lake water make-up pipeline are briefly described herein. The pipeline...
Combined Load Testing of Prestressed Concrete Cylinder Pipe
A series of combined load tests were run on prestressed concrete cylinder pipe in order to evaluate a proposed new method of design for pipe made to AWWA Standard C301. These tests involved...
Innovative Concept for Prestressed Pressure Pipe
A new design and manufacturing concept was developed by General Atomics for prestressed pressure pipe. With this new concept, patented in the U.S. and in the major industrialized nations,...
Performance of Pipe Spillways for Dams
The Soil Conservation Service has used several different kinds of pipe products for spillway conduits of dams. Materials with a shorter estimated life are used for smaller low hazard dams...
Failure of Prestressed Concrete Embedded Cylinder Pipe
In 1964, the Ontario Provincial Government undertook to supply water to the City of London (current population 300,000). The supply source was from Lake Huron near Grand Bend, Ontario...
Evaluation of Combined Load Tests of Prestressed Concrete Cylinder Pipe
Combined load tests of prestressed concrete cylinder pipe, presented by Tremblay in the proceedings of this conference, are analyzed. Data gathered during the tests includes first visible...
The Effect of Compaction on Buried Flexible Pipes
This contribution presents an analysis of the installation of flexible pipes in granular soil. The deformation of the pipe cross section is measured in field and laboratory tests. It is...
Analysis of Alternative Pipe Materials for a Major Public Water Agency
A major southwestern public water agency has historically specified the exclusive use of prestressed concrete cylinder pipe (PCCP) for large diameter water transmission mains. Due to the...
Twin Pipeline Crossing of the Fraser River
A new creek water supply was developed for the communities of Mission and Matsqui, British Columbia, Canada, in the early eighties. Over 60 kilometres of 450 mm to 900 mm diameter ductile...
Relining of Jordan Aqueduct, Reach 3
As pipelines approach their life expectancy, they may need to be replaced. Or in some instances, replacement is needed much sooner due to defective pipe. Normal replacement operations...