Nonlinear Finite Element Analysis of Experiments on Two-Story Reinforced Masonry Shear Walls
Nonlinear, static finite element analyses are being used for correlation with experiments conducted on one-story reinforced masonry shear walls, and for the prediction of and correlation...
Bond and Dowel Action of a Main Bar in a RC Beam
The bond and dowel action are analytically treated independently on each other in most cases. The bond behavior may be, however, much affected by the dowel action in structural members....
Consequences and Achievement of Supplemental Damping for Improved Seismic Performance
An earthquake resistant design philosophy which relies upon increased stiffness and damping rather than increased strength and ductility has been investigated. The effect of adding supplemental...
System Identification of a Large Structure Using Pseudo-Dynamic Test Data
This paper deals with structural modeling and the determination of optimal nonlinear models by applying system identification techniques to inelastic pseudo-dynamic test data from a full-scale,...
Seismic Design of Highrise Building with Mega Frame
The NEC corporation head office building is under construction at Shiba Minato-ku, Tokyo, Japan. This building is a highrise building of steel structure with the height of 180m. The structural...
Structural Considerations in Design and Construction Process of a 25 Story Office Building
This paper introduces an example in which a steel office building of 25 stories above the ground was constructed employing innovative techniques. One of them was the use of precast concrete...
Seismic Design of a Long-span Space Structure
This structure consists of a 5 layered complex shape of long-span steel roof structure, and reinforced concrete (RC) and steel reinforced concrete (SRC) supporting structures. The roof...
Implications for Limit State Design of Inverted V Braced Steel Structures
Inverted V braced steel structures with backup ductile moment-resisting frames forming a dual system, exhibit complex inelastic behavior under severe seismic excitations. Thus, current...
Seismic Load Effects on a Scaled Model Structure
A long term observation on a scaled steel braced frame model with intentionally reduced seismic strength is ongoing since 1983. This paper examines the seismic load effects of two earthquakes...
Buckling Criteria for Earthquake-Induced Overturning Stresses in Cylindrical Liquid Storage Tanks
Perhaps one of the most common forms of seismic damage to cylindrical liquid storage tanks made out of steel is buckling of the tank wall due to vertical overturning stresses. Buckling...
Nonlinear Analysis for the Aseismic Strength of Highrise Steel Frame With Semi-Rigid Joints by Pseudo-Elastic Approach
This paper suggests that the direct stiffness method is still useful in dealing with the nonlinear analysis for the aseismic capacity of highrise steel frame while the Pseudo-elastic approach...
Effects of Semi-Rigid Connections and P-? Forces on the Optimum Design of Seismic Steel Frames
By utilizing methods of optimality critera and constraint gradients, the minimum weight design of semi-rigid planar steel frames subjected to static and seismic excitations is presented...
Amelioration of Stirrup and Compression Reinforcement on the Ductility of Reinforced High-Strength Concrete Beam
18 rectangular high strength concrete beams were tested to investigate their ductile behavior. The results show that it will be more advantageous, for ductility, to choose the compressive...
The 1988 UBC Seismic Provisions for Steel Structures?An Overview
This paper will give the reader an introduction to the seismic design provisions for steel structures in the 1988 Uniform Building Code. Chapter 27 in the 1988 UBC now contains over ten...
1988 SEAOC and UBC Seismic Provisions
This paper highlights the major improvements to seismic design provisions incorporated in the 1988 Structural Engineers Association of California (SEAOC) 'Blue Book'...
Deformability of Reinforced Concrete Members
A large volume of test data has been evaluated to establish deformability of reinforced concrete beams, columns, and structural walls in the inelastic range. Experimentally observed deformation...
Reevaluation of Reinforced Concrete Slabs Subjected to Blast Effects
Failures in reinforced concrete shallow-buried structures subjected to the effects of severe dynamic loads are reevaluated by employing a modified Timoshenko beam formulation which includes...
Assessment of Transmission Line Foundations
Electric utilities are faced with the need to build new transmission lines or to upgrade existing lines to meet future demands. Because of economic constraints and the difficulty of obtaining...
Making Amends with Nature
The U.S. salmon population has been decimated in the last half-century, principally because of hydropower. In the nation's focus on alternate and clean energy sources, fish...
The Church on Stilts
Christ Church Cathedral is an Anglican church situated in the heart of downtown Montreal. Constructed in 1859, it is a perfect example of English neogothic architecture, characterized...
Return to search