Seismic Capacity Evaluation of SRC Buildings
The Japanese standard for seismic capacity evaluation of existing composite steel and reinforced concrete (SRC) buildings was introduced. As it developed, based on the previously established...

Composite and Mixed Construction in Czechoslovakia
Various composite and mixed systems have been used in Czechoslovakia. Special attention is focused on design methods, effective construction, and material savings. Current developments...

Seismic Strengthening of Existing RC Buildings
Seismic strengthening of existing reinforced concrete (RC) frame buildings by the use of steel braces or panels was studied experimentally. A special joint between steel elements and the...

Seminar Summary and Research Needs
All the papers presented in the technical sessions of the seminar are summarized and, in some cases, commented upon. The needed research in composite and mixed construction is described....

Binding and Bonding Concrete to Composite Columns
Composite interaction between concrete encasement and structural steel shapes is limited unless lateral ties and/or mechanical attachments insure such interaction until desired strength...

A Road to Recovery
Inspections of the Golden Gate Bridge revealed that the bridge had localized corrosion near its expansion joints, corrosion of its reinforcing steel, and was severely contaminated with...

Water Quality Modeling of Key Largo Coral Reef
A numerical model called CORALSIM has been developed for the Key Largo Coral Reef National Marine Sanctuary in the Florida Keys. The model was developed as a management tool to study the...

Failure of a Large Reinforced Concrete Pipeline
This paper describes the damage that occurred when a landslide overloaded an 11 ft diameter reinforced concrete pipeline. The 8 ft lengths of pipe, each of 11. 5-in. wall thickness, were...

Buried Fiberglass Pipe Response to Field Installation Methods
In 1970 near Yuma, Arizona, a field test installation of 30 inch diameter fiberglass pipe was constructed. Twelve years later the pipeline was remeasured. Measurements of pipe profile,...

Strains Induced by Combined Loading in Buried Pressurized Fiberglass Pipe
In 1983 Owens Corning Fiberglas and Utah State University collaborated on a study of combined strain behavior of fiberglass pipe to quantify the bending strain reduction as a function...

Long Term Testing of Centrifugally Cast Glass Fibre Reinforced Plastic Pipes (RIRP)
The paper discusses testing of pipe manufactured by centrifugal molding. The tests included external load tests, internal load, hydrostatic internal pressure, and cyclic internal pressure....

Buried Fiberglass Pipe Performance and Installation Requirements and Design Calculations in International Standardization
This paper elaborates on a proposed standard covering details of fiberglass pipe buried installation requirements and criteria for selection of pipe stiffness. It also discusses the selection...

Successful Use of Centrifugally Cast Glassfiber Reinforced Plastic (GRP) Pressure Pipes for Public Works in Sweden
Centrifugally cast GRP pipes were introduced in Sweden 17 years ago for industrial applications mainly as a gravity pipe. The process of pipe manufacturing as well as the pipe itself and...

Proportioning Reinforcement for Buried Concrete Pipe
The proportioning of reinforcement between inner and outer cages that is specified in ASTM Standard Specification C76 for concrete pipe in sewer and culvert applications is examined in...

Shear Stresses in Composite Masonry Walls
The behavior of composite masonry walls subjected to inplane loads is a subject that has received little attention during the last few years. The small amount of experimental and analytical...

Tension-Compression Test of a Concrete Specimen Via a Structure Damage Theory
The concrete sample is assumed to consist of a large number of aggregates and cement paste. Their material properties are assumed to be perfectly elastic. The effective elastic property...

Composite and Mixed Construction
Steel and reinforced concrete are frequently combined in composite or mixed structural systems. This combination generally results isn greater economy and safety than could be achieved...

Specifications for the Design and Construction of Composite Slabs and Commentary on Specifications for the Design and Construction of Composite Slabs
Composite slab construction is defined as a system comprising normal weight or lightweight structural concrete placed permanently over cold-formed steel decking in which the steel deck...

Membrane Sealing of Rouchain Dam
A synthetic sealing membrane was used to prevent excessive leakage through the facing of an embankment dam. The works, which were completed rapidly and at low cost, enabled the reservoir...

The R. D. Bailey Dam, a Concrete-Faced, Earth-Rockfill
A case history for the R. D. Bailey Dam, describing its comparatively unique design and construction considerations, and its operational performance since initial reservoir filling in...

 

 

 

 

Return to search