Bridges and Transmission Line Structures
This volume on Bridges and Transmission Line Structures contains papers from ten sessions and one plenary session of the 1987 ASCE Structures Congress. Eight sessions cover bridges. A...
Earthquakes Will Not Damage This Bridge
A California pipeline bridge has been retrofitted with isolation bearings that damp earthquake shocks. The bridge over Southern California's Santa Ana River carries the Upper...
The Just-in-Case Factor
Computer analysis allows bridge designers to take a more precise look at the old structural principle of redundancy. No one can define redundancy, but everybody knows what it means. Two...
Twisting in the Wind
Wind tunnel tests are being used increasingly to test the aerodynamic stability of bridges. Many designers think these tests should be used early in the conceptual design stage, rather...
Artist in Wood Structures
Julius Natterer is chairman on the Institute for Wood Structures at the Federal Institute of Technology in Lausanne, Switzerland, and designer of more unusual or unique wood structures...
Concrete Strength Record Jumps 36%
A Seattle building now going up has 19,000 psi concrete, the strongest ever in conventional structures. It costs three times as much as conventional concrete, so will not be widely used....
Journal of Cold Regions Engineering
The Journal of Cold Regions Engineering publishes practice- and research-oriented articles from any area of civil engineering that is substantially related to cold regions. Topics include ice engineering,...
Carmen-Smith Uprate & Modernization
The Carmen-Smith Powerhouse is located on the upper McKenzie River, 75 miles northeast of Eugene, Oregon. Carmen's two nearly identical 42. 1 MVA vertical hydroelectric turbine...
Rehabilitation of a Pump/Turbine
Between 1964 and 1968, eight 212 in pump discharge diameter Baldwin-Lima-Hamilton vertical pump/turbines with Westinghouse motor/generators were installed in Philadelphia Electric Company's...
Fishery Issues Slow Boardman River Redevelopment
At issue was the requirement of the Michigan Department of Natural Resources (MDNR) and the U. S. Fish and Wildlife Service to require the establishment of fish ladders at the hydro sites....
Seismic Isolation System for a Floating Dry Dock
The seismic isolation system consists of two dolphins, each a relatively large-diameter cantilevered steel pipe pile anchored in Franciscan rock, and buffered connections to the floating...
Steel Poles?Past, Present and Future
When using steel pole structures, construction possibilities are limitless. Of all the options available, tubular steel structures provide the most versatility for transmission line construction....
Lattice Tower Design Using Cold-Formed Shapes
The use of cold-formed shapes in lieu of hot-rolled angles may lead to major changes in the design of lattice transmission towers. The design procedure of the new shapes is more creative,...
Cold-Formed Angles for Transmission Towers
Cold-formed members enable the engineer to design transmission towers that may be more cost-effective than those built with hot-rolled angles. Members can be designed to closely fit the...
Design and Test of Cold Formed Steel Members
Latticed systems represent the most spread and low-cost solution for electrical trasmission towers, when ground conditions do not affect the design choice. Steel angles have been used...
Bolted Connections for Steel Towers
Laced electrical transmission towers require on-site assembly. Consequently, the number of bolts and pieces are important considerations in the total cost of the structures. ASTM A394(1)...
Strain Gaging and Data Acquisition at the TLMRF
Strain gages are the major source of data for the TLMRF (Transmission Line Mechanical Research Facility) research program. Measurement of member loads and bending moments in lattice towers...
Special Pile Foundations for a Coastal Permafrost Site
The design of the plant's foundations had to address several challenging geotechnical conditions. These included (1) 'warm' (close to 32 degree F)...
Adfreeze Strength of Ice to Steel Pipe Piles as a Function of Temperature
A study was initiated to determine the adfreeze bond strength between steel pipe piles and freshwater ice as a function of temperature. Tests were conducted at an average strain rate of...
Repair Welding of Arctic Offshore Structures and Vessels
This paper describes the welding procedure development for repair or field modifications of offshore drilling structures and vessels made with several different steel grades produced for...
Return to search