Generic Problems
Generic Problems are basic problems in structural mechanics that recur frequently, have been investigated experimentally and involve the behavior of elements or components found in many...

Seismic Design of Multi-Story, Wood-Framed Buildings
The seismic design and analysis of wood-framed structures is relatively simple; however, the challenges that present themselves within this design medium are shear and overturning force...

Stabilization of South Texas Soils with Fly Ash
The expansive soils of south Texas have traditionally been stabilized with lime or Portland cement. As an alternative, a class F fly ash was tried to stabilize expansive soils obtained...

Enzyme Enhanced Stabilization of Soil and Fly Ash
The purpose of this research was to determine if enzymes could be utilized to increased the strength and stability of soil mixed with fly ash. Samples were prepared with and without the...

A Study of Engineering Properties of a Clay Modified by Ash and Slag
Fly ash from power plants and slag from steel mills are two industrial solid wastes. These wastes can be utilized as soil stabilizers. In this study, a clay with low plasticity is mixed...

Driven Then Pushed Minicone Tests in a Sand Chamber
For a general knowledge on the Standard Cone Penetrometer test and its uses the reader is referred to the work of Briaud and Miran (1991). For this study (Khalaf and Briaud, 1992) a smaller...

Lateral Loading Curves from Pressuremeter Tests
The large drilled shafts for the proposed Klamath Falls Bridge, which are to be founded in diatomaceous silts, were to be designed to withstand earthquake induced large cyclic loading....

Evaluation of Dilatometer Method to Determine Axial Capacity of Driven Model Pipe Piles in Clay
The flat Dilatometer (DMT) provides a unique approach to estimate the effective stress axial capacity of driven displacement piles in clay. An investigation using this approach was performed...

Drilled Shaft Friction Evaluation via Pullout Tests
The history, development, and field test results of a small-scale 'pullout' test to assess the skin friction (fsu) for drilled shafts socketed in...

Verification of Deep Foundations by NDT Methods
Deep foundations are designed using static analysis techniques and the soil strength and structural integrity are then confirmed by static load tests. However, static tests are time consuming...

Piles for Marquette University Math Building
This paper presents a comparison of static pile capacity predictions using CPT cone resistance results with results of a test pile program and production pile driving. Pile capacity prediction...

Drilled Shaft Side Resistance in Clay Soil to Rock
An evaluation is made of available field load test data for the axial side clay soils to hard rocks. Conventional total stress interpretations by the alpha method are used to examine the...

Execution and Evaluation of High Capacity Caisson Load Tests in Glacial Deposits
As part of the Boston Harbor clean up project, the new 1,000 mgd Deer Island Sewerage treatment plant includes ten 240 feet high egg-shaped 'residuals' tanks. Contract documents called...

Bi-Directional Load Testing of Shafts to 6000 Tons
This paper describes the use of Osterberg cells (O-cells) to perform bi-directional load testing on full size production drilled shafts for a major bridge foundation near Owensboro, Kentucky....

Load Testing of Permanently Cased Drilled Shafts Founded in Hartford Shale
The axial and lateral load testing of three, 30 inch (76cm) diameter, permanently cased drilled shafts is analyzed herein. The prototype shafts were founded in (or on) Hartford Shale bedrock,...

Perimeter Load Transfer in Drilled Shafts in the Eagle Ford Formation
Results of six full-scale compression loading tests at four sites in the Dallas area are considered. Compressive strengths (qc) of the rock varied...

Side Resistance of Drilled Shafts in the Denver and Pierre Formations
Results of load tests on drilled shaft foundations in Upper Cretaceous shales are described and evaluated. Three load tests were conducted on shafts in the Denver Formation, in Denver,...

Behavior of Instrumented Model Piers in Manufactured Rock with a Soft Layer
A laboratory test apparatus has been used to study the side resistance of piers socketed into manufactured soft-rock masses. The results of four tests are reported, three of which included...

A Laboratory Procedure for Partial-Wetting Collapse Determination
Partial wetting results in partial collapse, which is linked to the reduction in soil suction caused by wetting. The laboratory procedure presented in this paper represents a modification...

The Hazard In Using Probabilistic Seismic Hazard Analysis
Probabilistic seismic hazard analysis has been used extensively for major dams; nuclear power plants; liquefied petroleum gas installations; repositories for dangerous wastes; sensitive...

 

 

 

 

Return to search