Vibration of Composite Floors
An AISC/CISC guideline on floor vibration is being prepared to help practitioners design to avoid floor vibration problems and to remedy problems that occur in practice. This paper provides...

Achieving Level Composite Steel Floors
Constructing deflected composite steel floors that are level is a complex operation, and one which requires cooperation and an exchange of information between the structural engineer and...

Ambient Vibration Response of a Long Span Bridge
Natural frequencies, mode shapes and damping characteristics for a long-span cable-stayed bridge were experimentally determined from a series of ambient vibration tests for both the cantilever...

Acoustic Emission Monitoring of Stressed Composite Bars
In this study, Acoustic Emission (AE) technique is used to monitor the behavior of composite bars subjected to direct tension. Aramid Fiber Reinforced Plastics (AFRP) bars were loaded...

Remote Monitoring of a Stressed Timber Bridge Deck
The long term behavior of a CCA treated stressed timber deck bridge is being monitored, at present, using a remote data acquisition system. The bridge which is located in Gray, Maine was...

Structural Analysis in Context
The issues of what student should learn about structural analysis and how it should be taught are explored considering the purposes of structural analysis in engineering practice and the...

Construction of CCM Overtopping Protection on Three Parkway Dams
Cellular concrete mat (CCM) systems have been installed as overtopping protection on three small embankment dams along the Blue Ridge Parkway. Based on field tests by others and on the...

Remedial Works at Troneras and Miraflores Dams in Colombia
The 38 m high Troneras and the 55 m high Miraflores earth dams were built in the period 1959-1965. The dams are composed of residual soils and founded on a deep residual overburden. Significant...

Liquefaction Potential Leads to Dam Reconstruction
Results of a visual inspection of the Dundee Dam conducted in 1982 revealed the presence of seepage on the downstream toe of the left embankment. Subsequent subsurface explorations and...

Construction and Verification of Ground Improvements at Mormon Island Auxiliary Dam
Mormon Island Auxiliary Dam, part of the Folsom Dam and Reservoir Project near Sacramento, California, is founded on alluvial materials that were dredged and processed for gold on several...

Trial Lake Dam Reconstruction
Trial Lake Dam is located in the Uinta National Forest in Central Utah at an elevation of about 10,000 feet. The dam is 50 feet high and stores 1,700 acre-feet of water for downstream...

Hydration Properties of Shotcrete with an Accelerator Based on Calcium Aluminate
A new powder-type accelerator based on calcium aluminate has been used for shotcrete in underground construction. This accelerator can be applied to all types of shotcreting. The shotcrete...

Steel Fiber Reinforced Shotcrete?An End-User Prospective
Nearly 15 years of experience demonstrates that steel reinforcing fibers in shotcrete offer considerable advantages to all end-users: designers, contractors and owners. These include demonstrable...

Large Scale Testing of Shotcrete
A large scale test program was carried out to evaluate the relative roles of steel fiber and mesh reinforced shotcrete for hard rock stabilization. The most realistic conditions in a tunnel...

What Does Bring Ductility to Steel Fibre Reinforced Shotcrete?
It is generally accepted that ductility is the main characteristic of SFRS. Tests on scale 1/1 have been conducted to determine the influence of ductility on the bearing capacity and crack...

Design of Tunnel Lining from Shotcrete in Combination with Anchors
The method of designing tunnel linings from shotcrete in combination with anchors is given in the paper. The method is based upon the solution of the plane contact problem for a double-layer...

Steel Fibre Reinforced Shotcrete Design
There is a need for introducing toughness and ductility in SFRS design. The Japanese Standard introduces the equivalent flexural strength, which characterizes SFRS toughness and allows...

Single-Shell Shotcrete Method
On a 60-m-long test stretch in the course of the construction of the Munich Subway the single-shell jointless shotcrete method was employed. In this case the standard cross section of...

Two Shotcrete Lined Tunnels in the United Kingdom
The paper describes two large diameter tunnels recently built in southern England where shotcrete has been used as the primary support. The design methodology is described together with...

Lattice Girders for Shotcrete Support
Lattice Girders complement the use of shotcrete for underground support by reducing the risk involved with using shotcrete alone for temporary or permanent lining of a tunnel or shaft....

 

 

 

 

Return to search