Uplift Resistance of Plywood and OSB Roof Sheathing
A test program to determine the resistance of plywood and OSB roof sheathing to uplift pressures created by wind flowing over a residential roof structure will provide valuable data to...
3-D Dynamic Analysis of the Brent-Spence Through-Truss Bridge
A three dimensional finite element model is developed for the free vibration analysis of main bridge. The model was calibrated by comparing the free vibration analysis results with ambient...
Bridge Evaluation Using a Hybrid Information System
The objective of this paper is to discuss the developments and implementation of a hybrid system consisting of a rule-based information system and hypermedia technology for use by inspectors...
Behavior of Tall Frame Combining Rigid and Semi-Rigid Connections
In this paper, the applicability of the mixed use of rigid and semi-rigid connections in the tall frame is discussed. It is tried. for 4-bay 8-storey frame to be numerically analyzed for...
Bridging the Gap Between Architecture and Engineering
Building design is interdisciplinary by nature. Indeed, the collaboration of architect and structural engineer is critical to the success of building design projects. Yet with few exceptions...
Aesthetic Issues in Timber Bridges
The vocabulary of visual design and several generally accepted major principles of visual design are reviewed in order to provide a 'context' for case studies of award-winning timber bridges....
Implementation of Passive Energy Dissipation Systems in the United States
Significant advances in the field of passive energy dissipation for improved structural seismic resistance have been made in recent years. Developments in research and analysis techniques...
Utilizing Visco-Elastic Dampers in the Seismic Retrofit of a Thirteen Story Steel Framed Building
A 13 story steel framed building in Santa Clara Country, California exhibited strong beating effects (torsional coupling) and prolonged building response as result of various seismic events....
When are Loads Taught? A Case Study and National Trends.
Several years ago, structures faculty of the Department of Civil and Architectural Engineering at the University of Wyoming revised their structures courses to meet several new educational...
Where do the Arrows Come From? Evaluating Structural Loads
Two elements of an undergraduate's structural education that are not treated well in most textbooks are (1) the development of correct loads and (2) load modelling-that is, how the load...
Long-Term Monitoring of Civil Structures using Smart Structures Techniques
A smart monitoring program for a hybrid concrete-steel building in Washington, D.C. has been developed. The building is currently being instrumented with a variety of strain and corrosion...
Design and Construction of Post-Tensioned Concrete Floor Systems
This is a summary of the original full length paper which is available from the author. This paper assumes a basic technical knowledge of reinforced concrete design and prestressed concrete...
A Probabilistic Approach to the Response of Tall Buildings to Wind Loadings
Tall buildings constructed in recent years are light in weight, flexible and low in damping. This is the consequence of using lighter material with higher strength, and fewer interior...
Extreme Winds Estimation by `Peaks Over Threshold' and Epochal Methods
With a view to applying the 'peaks over threshold' method to the estimation of extreme wind sped data, we perform Monte Carlo simulations for which the parameters of the population distributions...
Effects of Sea Surface Movement on Offshore Structures
Examinations are made of the effects of the sea surface movement on the fundamental model response of deep-water, Wave-excited offshore structures. These effects are accounted for by using...
Evaluation of Cast Iron Columns for Safety and Reliability
Cast iron columns exist in numerous vintage buildings. Alterations to these buildings often require analysis and modification of the structural system. This paper identifies codes that...
Messeturm Tower: Frankfurt, Germany
A 256 meter (840 feet)tall office tower, currently the tallest building in Europe, has been constructed in Frankfurt Germany. The 7- story structure with 85500 square meter (920,000 square...
Design and Analysis of the 712 Fifth Avenue Structure
New York City's 712 Fifth Avenue is an extremely-slender concrete tube tower. This text addresses the structure's lateral structural system, wind analysis, computer model, thermal analysis...
The Slender Tower of 52-54 East End Avenue
The structural system for the 52-54 East End Avenue project is presented. The 40 story residential tower with as aspect ratio of 12: 1 is one of the most slender buildings constructed...
Gothic Structure and Design: Narbonne Cathedral
Viollet le Duc considered Narbonne Cathedral to be one of the best constructed Gothic buildings in France. The ambulatory piers are single courses of stone bonded into adjacent walls....