Considerations in Applying the 1985 HCM Procedures
The paper examines the impact of critical assumptions in the 1985 Highway Capacity Manual (HCM) procedures on the resulting measures of effectiveness -- volume/capacity ratio, delay, and...
Evaluation of Sediment Transport and Friction Factor Equations Using MOBED
Three sediment transport rate equations and the same number of friction factor equations for mobile boundary channel flows were evaluated using a mobile boundary flow model called MOBED....
Digestor Do-Over
Digesters at 6 Orange County (Calif.) wastewater treatment plants needed drastic odor control rehabilitation. Repairs included epoxy patching to cracked domes, installation of a geomembrane...
Uncertainty Analysis of Field Turbine Performance Measurements
This paper presents comprehensive uncertainty analyses of two different flow measurement methods for field tests on turbines. The 'water to wire' efficiency was...
Laser-2-Focus Flow Measurements in the Runner of a Bulb Turbine and Comparison with Calculation
Flow measurements are presented, which were carried out near and inside the 4-blade runner of an axial model bulb turbine of double adjustable type. These measurements were performed by...
Hydraulic Machines Model Acceptance Tests
The article begins with a description of the modern test installations, giving the dimensions of the models most frequently used and the head heights. Attention is then given to the most...
Thermal Monitoring of Leakage Through Dams
The technique involves very accurate temperature measurement at shallow depth below the reach of the surface diurnal cycle. Temperatures respond to subsurface water movement (with advective...
Negotiating Environmental Protection Measures with Resource Agencies: Twin Falls and Weeks Falls Hydroelectric Projects, Washington
The planning and licensing process for the Twin and Weeks Falls Projects involved resolution of numerous regulatory and environmental issues, including the need for cumulative impact analysis...
Run-of-River Controller for Hydro Plants
New York State Electric and Gas Corporation has installed programmable run-of-river (ROR) controllers at five of their plants. Each of these plants has either two or three units with installed...
Simulation of the Pit 3, 4 and 5 Hydroelectric Project Using the USFWS Instream Temperature Model
The Pit River in Shasta County, California, is the site of the Pit 3, 4, and 5 Project (Project). A two-year Bald Eagle and Fish Study was initiated in March 1983. As part of the overall...
Computer Modeling for a Power Intake
This paper describes the application of an existing computer model to respond to environmental requirements for a small scale hydroelectric power plant being developed by Allegheny Electric...
Adfreeze Strength of Ice to Steel Pipe Piles as a Function of Temperature
A study was initiated to determine the adfreeze bond strength between steel pipe piles and freshwater ice as a function of temperature. Tests were conducted at an average strain rate of...
Hot Sand for Improved Traction on Icy Roads
Experiments were performed to determine if heating sand prior to spreading it on icy roads would improve the skid resistance of the road more than cold sanding. Tests were made on a full-scale...
Design and Monitoring of an Ice Drill Pad
An ice pad was sucessfully designed and built to provide a suitable foundation for an exploratory drill rig in the National Petroleum Reserve of Alaska in early 1985. Design considerations...
Development of a Self-Heating Thermal Probe for Saline Permafrost
Geothermal modelling and prototype testing are described to support the development of a self-heating thermal probe. This has application for in-situ determination of the amount of unfrozen...
Installation of Thermistor Strings in Test Borings: A Comparison of Methods and Results
Several test borings were instrumented with two thermistor strings, one inside and one outside an air-filled PVC casing to compare readings of both thermistor strings and the stability...
Monitoring Techniques for Thermosyphons
Two-phase thermosyphons used for passive soil refrigeration are monitored using a variety of techniques ranging from visual infrared scanning to measurement of internal pressures. Methods...
Ground Temperature Monitoring Cominco's Red Dog Project
Procedures are available in the literature for estimating subsurface thermal characteristics of foundation soils in cold regions using published climatic characteristics for a given area....
A Thermal Analysis of Pavement Thawing
This research focuses on identifying the spring thawing period for the purpose of timing load restrictions on low to medium volume roads in frost-susceptible areas. Cases evaluated include...
Arctic Stream Scour: A Case History
A small arctic stream on the North Slope of Alaska was monitored through one hydrologic cycle. The flow rate of the stream and the progress of its erosion through a breach into an adjacent...
Return to search