Seismic Study of a Cable-Stayed Bridge
The focus of this paper is to investigate the non-linear and linear behavior of a cable-stayed bridge in a seismic environment. Three design features of a cable-stayed bridge are studied:...

Seismic Issues in Structural Engineering Codes and Practice
It is necessary that we view the seismic events in an overall probabilistic mode and determine the criteria for acceptable damage at various levels of service in the building. We need...

Aesthetic Considerations in the Design of a Stack Extension
The Connecticut D.E.P. mandated increase in height of the boiler stack at Backus Hospital in Norwich, CT presented many problems. Adding a new 45 foot vertical section atop the old brick...

Civil Engineering and Civic Monuments: The Commissioning, Design and Public Perception of Urban Infrastructure Projects
This paper analyzes the roles that some infrastructure projects play as civic monuments and public places, and how these functions interact with their technical performance and utility....

Bridging the Gap Between Architecture and Engineering
Building design is interdisciplinary by nature. Indeed, the collaboration of architect and structural engineer is critical to the success of building design projects. Yet with few exceptions...

Aesthetic Issues in Timber Bridges
The vocabulary of visual design and several generally accepted major principles of visual design are reviewed in order to provide a 'context' for case studies of award-winning timber bridges....

Implementation of Passive Energy Dissipation Systems in the United States
Significant advances in the field of passive energy dissipation for improved structural seismic resistance have been made in recent years. Developments in research and analysis techniques...

Utilizing Visco-Elastic Dampers in the Seismic Retrofit of a Thirteen Story Steel Framed Building
A 13 story steel framed building in Santa Clara Country, California exhibited strong beating effects (torsional coupling) and prolonged building response as result of various seismic events....

Development of Hardwood Glulam Timber Bridge Standards
Design standards and specification for 5.5 to 27.4 m(18 to 90 ft.) clear span hardwood glued laminated (glulam) highway bridges have been developed and are available from the Pennsylvania...

Design and Field Performance of a Metal-Plate-Connected Wood Truss Bridge
This paper describes an on-going study on the design and performance attributes of an experimental wood-truss bridge. This is believed to be the first roadway bridge application of metal-plate-connected...

When are Loads Taught? A Case Study and National Trends.
Several years ago, structures faculty of the Department of Civil and Architectural Engineering at the University of Wyoming revised their structures courses to meet several new educational...

Where do the Arrows Come From? Evaluating Structural Loads
Two elements of an undergraduate's structural education that are not treated well in most textbooks are (1) the development of correct loads and (2) load modelling-that is, how the load...

Long-Term Monitoring of Civil Structures using Smart Structures Techniques
A smart monitoring program for a hybrid concrete-steel building in Washington, D.C. has been developed. The building is currently being instrumented with a variety of strain and corrosion...

Design and Construction of Post-Tensioned Concrete Floor Systems
This is a summary of the original full length paper which is available from the author. This paper assumes a basic technical knowledge of reinforced concrete design and prestressed concrete...

A Probabilistic Approach to the Response of Tall Buildings to Wind Loadings
Tall buildings constructed in recent years are light in weight, flexible and low in damping. This is the consequence of using lighter material with higher strength, and fewer interior...

Analysis of Unstiffened and Stiffened Tubular Members Under External Pressure and Structural Loads
This paper summarizes some important results concerning the ultimate capacity of stiffened and unstiffened tubes under combined loading. Such tubes are candidates for use in offshore structures...

Evaluation of Cast Iron Columns for Safety and Reliability
Cast iron columns exist in numerous vintage buildings. Alterations to these buildings often require analysis and modification of the structural system. This paper identifies codes that...

Messeturm Tower: Frankfurt, Germany
A 256 meter (840 feet)tall office tower, currently the tallest building in Europe, has been constructed in Frankfurt Germany. The 7- story structure with 85500 square meter (920,000 square...

The Slender Tower of 52-54 East End Avenue
The structural system for the 52-54 East End Avenue project is presented. The 40 story residential tower with as aspect ratio of 12: 1 is one of the most slender buildings constructed...

Gothic Structure and Design: Narbonne Cathedral
Viollet le Duc considered Narbonne Cathedral to be one of the best constructed Gothic buildings in France. The ambulatory piers are single courses of stone bonded into adjacent walls....

 

 

 

 

Return to search