Geotechnical Judgment in Foundation Design
This paper summarizes the initial findings of a research project to investigate the judgment-making process of foundation engineers. Solutions for a typical design problem were solicited...
Structural Foundation Practices for Highway Projects
The state-of-practice by State transportation agencies, in the area of structural foundations, is compared between the late 1970's and the present. The structural foundation...
Analysis of Pile Load Tests at Lock and Dam 26
This is a summary of the results collected during the extensive load test program performed by the U.S. Army Engineer District, St. Louis, during the construction of the new Lock and Dam...
Comparative Performance of Two Pile Types
This paper reports on the pile driving and load bearing characteristics of the two pile types driven at a plant site in Sumatra, Indonesia. Nine prestressed concrete piles were driven...
Pile Foundation Construction Practice in Stiff Clays with Dense Granular Layers
A survey was conducted recently in conjunction with a project located in the San Francisco Bay Area to ascertain the general pile driving practice in stiff overconsolidated clays interbedded...
Augered Cast-in-Place Piles
Development of the augered cast-in-place pile system from origination in the late 1940's to the present state of the art is presented, with methods of pile placement, including...
Contribution of Soil Freeze to Pile Capacity
In order to investigate the magnitude and rate of increase in load capacity for piles installed in clayey soils, a series of load tests were performed at various intervals of time following...
Owner and Designer Advantages Derived from Use of Construction Consultant
There are two significant ways that an experienced construction consultant can assist both the owner and the designer/engineer in obtaining an economical and practical structure. Constructibility...
Some Observations on Undrained Side Resistance of Drilled Shafts
A data base of 106 field load tests (65 in uplift and 41 in compression) is used to evaluate the undrained side resistance of drilled shaft foundations. The total stress or alpha (?) method...
Load Tests on Bored Friction Piles in Clay
For the first time in Boston, Massachusetts, U.S.A., uncased bored friction piles in clay were used to support a six-story residential structure over a 60- to 75-foot (1.83 to 22.9 m)...
Full Scale Caisson Load Test for the Milwaukee Center
Top-down procedures were proposed to construct four basement levels for a major high-rise building development in Milwaukee, Wisconsin. Drilled caisson foundations were the preferred means...
Drilled Shafts?A Database Approach
A database of 43 drilled shaft load tests of high quality has been developed to study parameters that affect the axial behavior of drilled shafts and methods of analysis to predict axial...
Interpretation of Load Tests and Drilled Shafts?Part 3: Lateral and Moment
Existing interpretation methods for lateral and moment load tests are reviewed critically, and a qualitative and quantitative comparison is made for selected methods. A new method is proposed...
Nondestructive Testing of Deep Foundations with Sonic Methods
Nondestructive testing and evaluation (NDT&E) of deep foundations with three sonic methods is discussed. Case history investigations described include test records from drilled...
Geophysical and Nuclear Methods for Non-Destructive Evaluation of Caissons
Non-destructive testing techniques were used to confirm the concrete integrity on the caisson foundations for the 45-story Ohio Corporate Headquarters building in Cleveland, Ohio. The...
Bearing Capacity of Shallow Strip Foundation on Strong Clay Underlain by Weak Clay
Laboratory model test results for the ultimate bearing capacity of shallow strip foundations supported by a stiff clay layer underlain by a weaker clay layer have been presented. The model...
Rectangular Footing on Nonhomogeneous Elastic Half Space
The problem of a rectangular footing or a strip footing on a nonhomogeneous elastic half space is studied in this paper. The medium is assumed to be isotropic with a variable shear modulus...
Performance of a Large Ribbed Mat on Cohesive Soil
The performance of a 678-ft by 304-ft (207-m by 93-m) ribbed concrete mat was studied to provide improved soil input parameters for design. The mat was constructed on a low plasticity...
Bearing Capacity of Shallow Foundation on Granular Column in Weak Clay
Laboratory model tests results for the ultimate bearing capacity of shallow rectangular foundations supported by granular columns made in weak clay have been presented. In all cases, the...
Interpretation of Instrumented Driven Steel Pipe Piles
This paper presents the results of a series of studies on the behavior of driven close-ended steel pipe piles. Extensive field explorations and geotechnical analyses have been carried...