Stochastic Beams on Elastic Foundation
The finite difference method is applied to the second-moment analysis of beams on elastic foundation with random characteristics. The method is simpler than the stochastic finite element...

Arctic Foundation Selection: A Decision Matrix
An idealized matrix diagram is presented of the decision making process involved in determing an economic Arctic foundation type that is best suited to the proposed above-grade structure....

Standards for Pile Load Tests in Permafrost
A requirement exists to establish standard procedures for conducting pile load tests in permanently frozen soils. The methods outlined in the ASTM Standards for piles in thawed soils do...

Attenuating Creep of Piles in Frozen Soils
Results of several long-term creep tests of piles in frozen soils are analyzed; the primary or attenuating creep is predominant in most cases. For effective design of pile foundations...

Creep of a Strip Footing on Ice-Rich Permafrost
Creep settlement tests were performed on a strip footing founded on the surface of ice-rich aeolian silt permafrost. The tests consisted of applying four step loadings to a 10 in. (25....

Predicted and Measured Performance of a Foundation
The predicted and measured short term foundation behavior of a 28 story building in downtown San Antonio, Texas is reported. The soil is a stiff to hard clay and clay shale. The design...

Geotechnical Behavior of Underreams in Pleistocene Clay
Enlarged bases are often constructed in cylindrical drilled-and-cast-in-situ foundation elements (footings, bored piles) to increase their capacity. Enlarged bases that are cut mechanically...

Comparison of Caisson Load Tests on Chicago Hardpan
The results from two relatively recent instrumented caisson load tests from different sites on Chicago Hardpan are compared with a 'classic' large scale caisson...

Observations on Load Tests for Drilled Shafts
This paper focuses on three specific areas pertaining to load tests for drilled shafts: 1) basic considerations and load testing procedures, 2) interpretation of uplift load test information,...

Review of Repeated Axial Load Tests on Deep Foundations
A review of the literature is presented on the axial capacity of deep foundations subjected to repeated loads. Data are summarized on anchors, driven piles, and drilled shafts. In general,...

Abutment Seepage at Smithville Dam
After initial filling there was concern for the stability of Smithville Dam when higher than anticipated piezometric levels were experienced in the left abutment foundation. Concern heightened...

Seepage Control at Cochiti Dam, New Mexico
Significant design data, design assumptions and computations, and performance of the seepage control features provided at Cochiti Dam are summarized in this paper. The dam is a rolled...

Soldier Creek Dam Foundation Drainage
A possible mode of failure for Teton Dam, piping of erodible core material through unsealed foundation joints, was also concluded as being possible at Soldier Creek Dam, Utah. Evaluations...

The Use and Performance of Seepage Reduction Measures
The utilization and performance of various foundation seepage reduction measures from over 100 dams situated on pervious soils throughout the world has been reviewed. Summary discussions...

Designing and Monitoring for Seepage at Calamus Dam
Given the complex, pervious nature of the foundation for Calamus Dam, every effort has been made to incorporate design features that will reduce and control the anticipated large volumes...

Water Balance Approach to Prediction of Seepage From Mine Tailings Impoundments, Part II: Theoretical Aspects of Water Balance Approach to Seepage Modeling and Detailed Case History Results
Some of the most significant volumes and rates of interstitial tailings water discharge generally occurs during the initial portions of the primary consolidation process. During primary...

Use of Asphalt in Treatment of Dam Foundation Leakage, Stewartsville Dam
This paper presents the recent development and application of a hot asphalt grouting technique used to stop a 5,000 Imperial Gallons Per Minute (IGPM) (22,000 lpm) dam leakage under full...

Computer Applications in Grouting
The first use of computers during foundation grouting was tried by the Bureau of Reclamation on Ridgeway Dam in Colorado. It was very useful in monitoring real time down hole conditions...

Computer-Assisted Grouting Evaluation Systems
Electronic monitoring of cement pressure grouting at Ridgway Dam provides a powerful tool for geologic assessment of drilling and grouting results. Graphic surveillance and analysis of...

Grout Slurries?Thick or Thin?
In this paper some recent experiences in dam grouting in several countries are discussed where bentonite or Intraplast additives were used to control sedimentation, viscosity, grout density,...

 

 

 

 