Dynamic Response of Steel Fiber Reinforced Concrete
Extensive research has been done on the static properties of steel fiber reinforced concrete, but very little on the dynamic properties. A total of 20 beams was tested. The steel fiber...

Fatigue Damage Accumulation Under Stochastic Stress Histories
An extensive simulation study was performed to generate random Gaussian stress time histories from power spectral densities (psd's). The psd's of time histories were selected to represent...

Characterization of an ER Active Member
In the presence of strong electric fields (kV/mm), electrorheological (ER) materials change form viscous fluids to yielding materials. The class of ER materials used in this study have...

Wind Effects and Countermeasures During Erection of a Cable-stayed Bridge
The cable-stayed bridge over the Karnali River in the Kingdom of Nepal was completed in 1992. Extensive wind tunnel testing indicated the likely wind response during construction. Several...

Wind Studies of the Owensboro Bridge, Kentucky
Wind tunnel studies on the Owensboro Bridge are described in this paper, including 1:50 scale sectional model tests and 1:160 scale aeroelastic model tests. Comparisons are presented and...

Validation of the European Yield Model for Nailed Connections
Recent changes in National Design Specification for Wood Construction (NDS) connection design methods make it necessary to validate the European yield model (EYM) for nails. Test values...

Special Considerations in the Design of Connections for Recycled Wood/Plastic Composite Lumber
There is current work in the American Society for Testing and Materials (ASTM) to evaluate potential test methods for what they refer to as 'commingled' plastic lumber. This category covers...

Low Strain Dynamic Testing of Wood Piles Supporting an Existing Pier
This paper presents a case history where low strain dynamic testing was performed to test wood piles supporting an existing structure. Under consideration is a 183 m long wooden pier constructed...

Biaxial Testing of Brittle Repair Material for Rigid Pavements
Most codes of practice prescribe procedures for selecting patch configuration and material based on test devised for evaluating new pavement materials. This study is aimed at examined...

Control of Random Crack Formation in Portland Cement Concrete Pavements
Random crack formation in concrete pavements, which is mainly due to the development of tensile stress caused by temperature-induced volumetric change and shrinkage deformation at early...

Synopsis of a Manual on Structural Fire Protection
Structural Fire Protection : Manual of Practice was published in 1992 by the American Society of Civil Engineers. The Manual has two major parts. Part I (Chapters 1 to 3) introduces the...

Diaphragm Action of Cladding in Low-Rise Metal Buildings
An investigation of the contribution of cladding to the lateral stiffness of a metal building is presented in this paper. The diaphragm action of the cladding tends to redistribute the...

Current and Future Research in Steel Bridge Structures
The topics I have listed are ones which I am aware through discussions with various researches, designers, and industry representatives. The list of topics is presented as a starting point...

Pre-Engineered Short Span Steel Bridges
The American Iron and Steel Institute has developed a package to aid in expediting the design of short-span steel bridges for use by owners, designers, fabricators, and contractors in...

Compressive Strength of Masonry Prisms
Many factors affect the estimation of compressive capacity of a masonry prism. In the study the effects due to grout strength, mortar joints, block geometry and size, moisture content,...

Rigid Beam-To-Column Connection Detail for Circular Composite Columns
Steel pipes with relatively thin wall thickness and filled with high strength concrete have been used in building construction. Some of the advantages of this type of column include eliminating...

Aesthetic Considerations in the Design of a Stack Extension
The Connecticut D.E.P. mandated increase in height of the boiler stack at Backus Hospital in Norwich, CT presented many problems. Adding a new 45 foot vertical section atop the old brick...

Testing of Concrete Curtain Wall Panels Reinforced with FRP Grids
The objective of this paper is to evaluate the suitability of Fiber Reinforced Plastic (FRP) grids for use as a structural; reinforcement in concrete curtain wall panels. This paper describes...

Hi-Tech Seismic Rehabilitation of `Casino De Montreal'
The existing eight-story steel structure, built during 1966, lacked in lateral earthquake resistance and ductility requirements of the current building code. Introduction of friction-dampers...

Development of Hardwood Glulam Timber Bridge Standards
Design standards and specification for 5.5 to 27.4 m(18 to 90 ft.) clear span hardwood glued laminated (glulam) highway bridges have been developed and are available from the Pennsylvania...

 

 

 

 

Return to search