Ft. Lauderdale Wellfield Protection
Results of the study on groundwater contamination measurement and control are reported. The goal of this study was to ensure a safe and long-term supply of drinking water to the City of...

Testing of Permeable Materials for Retaining Contaminants in Subsurface Leachates
The use of a permeable, retentive treatment system could remove both organic and inorganic contaminants while still allowing flow. A testing procedure for determining the amounts of priority...

Permeability of Grouts Subjected to Chemicals
This paper presents the more recent results of a testing program which evaluated the long-term resistance to percolation of grouted soils, using acrylate, urethane and cement-bentonite...

Decreasing Clay's Permeability Using Aluminum Salts
The permeabilities of montmorillonite and kaolinite clays were reduced by precipitating aluminum hydroxide in the pores of the clay. The precipitate was formed by permeating the clays...

Design of Final Covers for Landfills
Final covers or caps are incorporated into a completed landfill to limit the amount of moisture percolation through waste materials. A properly designed final cover system provides the...

Evaluation of Landfill Leachate Recirculation
The effectiveness of leachate recycle as a leachate management technique has been evaluated at a landfill in central Pennsylvania where recirculation has been practiced for seven years....

Hydrogeologic Investigation of the Chillicothe, Ohio Landfill
A hydrogeologic investigation of a municipal waste landfill determined that the local surface and ground water are being polluted. Water quality monitoring and aerial photography were...

A Study of the Potential for Groundwater Contamination by Alcohol Blended Gasolines
This paper describes the increased solubility of gasoline-hydrocarbons in groundwater when alcohols are used as octane enhancement additives and the effects of 'gasohol versus...

Special Water Treatment in New Jersey
The New Jersey Department of Environmental Protection (NJDEP) performed a study on 'special water treatment'. The main goal of the project was to assess in detail...

Removal of Phenol from a Brine Aquifer: 2 Years of Operation
The article describes a pilot plant project to biologically treat groundwater polluted with phenols. The treatment scheme was based on laboratory tests, technical and economic analysis....

Chromium Removal by Activated Sludge
The behavior of chromium (Cr) in a laboratory-scale, activated sludge process was evaluated. Both pH and the oxidation state of Cr were confirmed as critical parameters for evaluating...

Full-Scale Automation of an SBR Wastewater Treatment Facility
Due to advantages offered by discontinuous wastewater processing, considerable attention has been given to the use of sequencing batch reactor (SBR). This paper will examine the implementation...

Removal of Trace Organics in MunicipalWastewater
This paper presents the results of three years of monitoring effluent quality from two treatment facilities for trace organic chemicals in Pima County, Arizona. Approximately thirty 24-hour...

Evaluation of Chlorine Dioxide and Ozone Preoxidation on Conventional Treatment and Direct Filtration
The renewed interest in the use of chlorine dioxide and ozone as preoxidants has focused mainly on their effectiveness on color and THM precursor removal and as disinfectants. This paper...

Experimental Verification of a Unified Chlorine-Ammonia Reaction Model
A model of the reacting aqueous chlorine-ammonia system is proposed which describes equally well the rapid 'breakpoint' oxidation of ammonia or the slow decomposition...

Slow Rate Sand Filtration Using a Zeolite Surface Amendment
The objective of the study was to obtain detailed information regarding amended filter performance at surface loading rates 2 to 4 times higher than standard flow rates. Experiments were...

Meeting Revised Drinking Water Regulations Using Conventional Treatment Methods
This paper discusses the removal efficiency of standard treatment processes for each of the four groups of contaminants. The evaluation of a process's capability to meet the...

Removal of Radon and Uranium from a water supply
The removal of Radon and Radium from drinking water with the help of granulated activated carbon (GAC) adsorption was investigated. A packed bed column was used for the purpose. It has...

Low Head Filtration Removal Efficiencies of Giardia Cysts, Coliform Bacteria, and Turbidity From Low Turbidity Water
The removal of Giardia cysts from low turbidity waters is of great concern in many areas of the United States. A pilot program was undertaken to determine if an established low head filtration...

Incinerating Dioxin Contaminated Waste at the USEPA Combustion Research Facility
The objective of the tests reported herein was to evaluate the incinerability of the toluene stillbottoms by determining whether 99. 9999% DRE could be achieved. All tests were performed...

 

 

 

 