Scour Inspection Using Ground Penetrating Radar
This paper examines the capabilities of Ground Penetrating Radar (GPR) for river bed scour inspection based on a study carried out by Clarkson University, Potsdam, New York in association...

Large-Scale Embankment Overtopping Protection Tests
The U.S. Bureau of Reclamation (Reclamation), Colorado State University (CSU), and the Electric Power Research Institute (EPRI) have an ongoing cooperative research effort to determine...

Ballast Water Treatment Effluent Dispersion Studies
Treated tanker ballast water is discharged form Alyeska Pipeline Service Company's ballast water treatment facility through a multiport diffuser into Port Valdez, Alaska. The discharge...

Evaluation of an Existing Scour Hole at the Castleton Bridge, a Tidal Crossing
Several fathometric surveys conducted in recent years showed a large depression or scour hole on the downstream southeast corner of the central pier of the Castleton Bridge over the Hudson...

Using Geophysical Data to Assess Scour Development
The development of scour holes in the Connecticut River near the new Baldwin Bridge has been documented by comparing geophysical records collected before (1989), during (1990), and after...

Local Scour Measurements at Bridge Piers in Alberta
A summary of local pier scour data collected by Alberta Transportation and Utilities (AT & U) over the past 30 years is presented. Several methods used to gather this data are...

Reference Surfaces for Bridge Scour Depths
Depth of scour is measured as the vertical distance between scoured channel geometry and a measurement reference surface. A scour depth measurement can have a wide range depending on the...

Uncertainty of Bridge Scour Estimates
Pier scour is the erosion of a streambed in the vicinity of bridge pier foundations. In this paper, fuzzy regression is used to develop two pier scour models, one based on crisp laboratory...

Field Examination of a Distribution System Water Quality Model
In the aftermath of the Safe Drinking Water Act (SDWA) of 1974, numerous models have been established to assess the quality of water and simulate its deterioration in distribution systems....

Evaluation of Historical Scour at Selected Stream Crossings in Indiana
Geophysical data were collected by means of ground-penetrating radar and tuned transducer systems to estimate the historical scour at ten bridges in Indiana. These geophysical data were...

Shale Scour at BNRR Yellowstone River Bridge, MT
Both the Burlington Northern Railroad and Montana Department of Transportation bridges across the Yellowstone river just south of Laurel, Montana, are founded on spread footings placed...

Analysis of Local Scour at Bridge Piers
Many studies have been performed on the cause and effects of local scour at bridge piers, and various prediction equations have been generated based on these studies. The general approach...

Two Full-Scale Tests of Class 3 Composite Beams
This paper presents two tests of continuous composite beams comprising two 7.5 m spans and two concentrated loads close to the intermediate support. Although the cross-sections on the...

Shear Connection in Composite Beams
This paper considers the influence of the shape of the deck profile on the shear connection of composite beams. It was found that the existing strength reduction factor can be unconservative...

Design of Composite Slabs for Vertical Shear
Three major modes of failure should be considered in the design of the positive moment regions of composite slabs incorporating profiled steel sheeting, viz.: flexure, longitudinal slip...

Seismic Performance and Composite Action of Older Structures
A study into the seismic performance of older steel structures is described. A review is made of the types of steel building construction completed during the period of interest, and the...

Development of Composite Slab with Truss-Typed Shear Connectors
This paper describes the results of the test on a steel-concrete composite slab with truss-typed shear connectors. This composite slab was recently developed. A series of tests were conducted...

Full-scale Tests on Composite Connections
Tests have been carried out on eight full-scale composite connections in which the columns were manufactured of concrete-filled steel circular hollow sections (CHS). The connections were...

Influence on Steel Deck on Composite Beam Strength
Results of a recent study were described in which 7 push-out tests and 4 composite beam tests were conducted. The results were consistent with other recent studies reported in the literature,...

Composite Beams with Headed Studs in Narrow Ribbed Metal Deck
This paper presents the results of sixteen push-out tests conducted to study the behavior of headed stud connectors in composite beams with narrow ribbed metal deck placed parallel to...

 

 

 

 