The Effects of Bolt Over-Tightening on Bolted Connections
This paper describes a portion of the research program being conducted on structural connectors which have been over-tightened. Direct-Tension Indicators (DTI) may be specified for use...
Externally Stiffened I-Beam to Box-Column Connections
This paper is concerned with I-beam to Box-column connections stiffened externally. Experimental and theoretical findings on full-scale connection models are highlighted. The performance...
Investigating the Behavior of a Lattice Structural Section
Tests were conducted on a fully instrumented lattice section assembled using various connection types (bolted or welded). The results of this study show that bolt slippage can have a major...
High Strength Shotcrete and Concrete on the SSC Project
This paper addresses the technical aspects related to the use of high strength shotcrete and concrete on the Superconducting Super Collider (SSC) project. 7,000 psi shotcrete and 8,000...
Steel-Concrete Interaction by Means of Film Sensors
By adapting a recently-developed technique based on the piezoelectrical properties of relatively thick films made of Polyvinyldifluor organic composites and extensively used in robotics,...
Shear Design Guidelines for Polyester Concrete Using Recycled Plastic
Previous research on the shear behavior of steel-reinforced polymer concrete (PC) beams has been very limited and no efficient design procedures have been proposed. In all the previous...
Dynamic Response of Steel Fiber Reinforced Concrete
Extensive research has been done on the static properties of steel fiber reinforced concrete, but very little on the dynamic properties. A total of 20 beams was tested. The steel fiber...
Fatigue Damage Accumulation Under Stochastic Stress Histories
An extensive simulation study was performed to generate random Gaussian stress time histories from power spectral densities (psd's). The psd's of time histories were selected to represent...
Practical Application of Tuned Liquid Damper for Tall Buildings
Performance of TLD, based on the full-scale measurement of an actual tall building, is discussed in this paper. Wind induced vibration of the SYP Tower was measured during a gusty day,...
Characterization of an ER Active Member
In the presence of strong electric fields (kV/mm), electrorheological (ER) materials change form viscous fluids to yielding materials. The class of ER materials used in this study have...
Special Considerations in the Design of Connections for Recycled Wood/Plastic Composite Lumber
There is current work in the American Society for Testing and Materials (ASTM) to evaluate potential test methods for what they refer to as 'commingled' plastic lumber. This category covers...
Low Strain Dynamic Testing of Wood Piles Supporting an Existing Pier
This paper presents a case history where low strain dynamic testing was performed to test wood piles supporting an existing structure. Under consideration is a 183 m long wooden pier constructed...
Biaxial Testing of Brittle Repair Material for Rigid Pavements
Most codes of practice prescribe procedures for selecting patch configuration and material based on test devised for evaluating new pavement materials. This study is aimed at examined...
Control of Random Crack Formation in Portland Cement Concrete Pavements
Random crack formation in concrete pavements, which is mainly due to the development of tensile stress caused by temperature-induced volumetric change and shrinkage deformation at early...
Fires Deemed to Have Tested Structural Performance
This paper provides an overview and progress report of a survey and study of fire incidents deemed to have tested the structural performance of large buildings. This ongoing effort was...
Consequential Fire Loads on Structures
Much less consideration has been given to the performance of modern structural and architectural systems during fires and to the minimization of damage that threatens the integrity of...
Synopsis of a Manual on Structural Fire Protection
Structural Fire Protection : Manual of Practice was published in 1992 by the American Society of Civil Engineers. The Manual has two major parts. Part I (Chapters 1 to 3) introduces the...
Estimation of Structural Damping of Buildings
The full-scale data on damping ratio are collected from 77 buildings within Japan. Almost all data are obtained from vibrations with a very small amplitude such as microtremor, man-power...
Earthquake Barrier Technology: Sliding-Friction Energy Dissipation
The first project in America to use friction damping was approved by the City of Los Angeles for the retrofit of a 10-story concrete frame building, designed to resist a Maximum Credible...
Wind Loads on Low Rise Structures: A Survey
Because of the large investment, high rise buildings are usually tested in a wind tunnel to provide the best wind loading information possible. Since low rise structures each represent...