Engineering Implications of Impoundment of the Indus River by an Earthquake-Induced Landslide
Historical records and physical evidence indicate that in the Himalayas of northern Pakistan a huge landslide dam was caused by an earthquake in 1840. The dam blocked the Indus River,...
U.S.-Japan Coordinated Program on Masonry Research
An overview of the U. S. -Japan Coordinated Program on Masonry Research is presented. The program consists of parallel efforts in Japan and the United States to develop design methods...
Sequential Earthquake Response of an Earth Dam
Sequential earthquake-response records of the well-instrumented Long Valley earth dam (Mammoth Lake area in California) are analyzed and engineering interpretations are made. The dam,...
Evaluation of Building Response Recorded During the Morgan Hill Earthquake
On April 24, 1984, the Morgan Hill Earthquake (Richter magnitude 6. 2) occurred within approximately 15 km of IBM Corporation's computer-equipment manufacturing facility located...
A Critical Look at Building Instrumentation in Earthquake Engineering
This paper discusses different issues and requirements existing in the area of building instrumentation. Strategies and types of equipment currently being used by the United States Geological...
Dynamic Testing of Structures Using the RESCUE Technique
This paper describes the most recent phase of an NSF supported program at SRI International to develop the technique of repeatable earth shaking by controlled underground expansion (RESCUE)...
Nonlinear Behavior of Precast Concrete Shear Walls under Simulated Earthquake Loading
This paper presents experimental and analytical results on precast concrete shear walls under earthquake loading. It was observed in both small scale models tested and the computer analysis...
Earthquake Analysis of Liquid Storage Tanks
In the design of modern liquid storage tanks, it is of technical importance to examine their safety against earthquake damage. The methodologies used in design do not account for the major...
Refinements in Pseudo-Dynamic Test Procedures
One of the major concerns in seismic testing is whether the loading conditions imposed on a structure adequately represent those that might occur during a major earthquake. Response simulation...
Building Records from 1984 Morgan Hill Earthquake
The dynamic response of 23 structures instrumented by the California Strong Motion Instrumentation Program was recorded during the magnitude 6. 2 (ML) Morgan Hill earthquake of 24 April...
Response of the San Juan Bautista 156/101 Bridge to the 1979 Coyote Lake Earthquake
Strong-motion accelerograms are used to examine the response of a multiple-span highway bridge to earthquake loading. Estimates of modal frequencies and damping values for the first two...
Performance of Existing Buildings: Results of Benchmark Structure Analyses Performed in U.S.-Japan Workshops
In response to the need for better understanding of current safety evaluation methodologies, three U. S. -Japan workshops have been conducted on the evaluation of the performance of existing...
Strengthening of a Multi-Story Building with Deflection Constraints
Occasionally the existing structural or nonstructural systems of a building being strengthened require the imposition of deflection constraints or limits in order to avoid an undesirable...
On Reliability-Based Structural Optimization for Earthquakes
Previous studies of reliability-based structural optimization have been extended in order to investigate the applicability of the linear statistical model in cases where random parameters...
Behaviour of Full-Scale Reinforced Concrete Structure on Realistic Foundation
A full-scale seven-story reinforced concrete building, tested as a part of U. S. -Japan Cooperative Research Program, performed well even under a severe earthquake loading condition. Nonlinear...
Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part I Gross Behavior
As a part of the U. S. -Japan Cooperative Research Program Utilizing Large-Scale Testing Facilities, a six-story, 2 by 2 bay, concentrically K-braced steel building was constructed in...
Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part II Local Behavior
The full-scale six-story concentrically K-braced steel building was subjected to Miyagi-Ken-Oki simulated earthquake whose peak intensity was 500gal. Local behavior of the test building...
Slab Participation in Frames under Lateral Loads
A unique opportunity to study slab participation was afforded by the U. S. -Japan Cooperative project on large scale testing. The data obtained from the full-scale 7-story building tested...
Earthquake Response Simulation Capacity of Pseudo Dynamic Testing?Experimntal Demonstration and Analytic Evaluation
The response accuracy of the pseudo dynamic test was evaluated from the shake table and pseudo dynamic tests conducted for a two story steel braced frame model. The obtained responses...
The Earthquake Barrier
The earthquake barrier protects buildings from the horizontal ground vibrations of an earthquake by installing a 'force barrier and an energy barrier' at the...
Return to search