Lateral Load Resisting Systems for Circular Buildings
The design of structural systems to economically limit inter-story drift and building acceleration for circular high rise buildings is presented within the framework of two recently constructed...

Criteria for Acceptable Wind-Induced Motions
This paper discusses criteria for evaluating acceptable wind-induced building motions. The paper draws on the results of moving room experiments and the performance of actual buildings...

Methods to Control Wind-Induced Building Motions
The wind-induced response of tall buildings can be controlled by global design modifications that can be placed in three broad categories, namely, design changes in structural systems,...

Construction of the Baytown Bridge, Houston
Connecting Baytown and LaPorte, the Baytown Bridge is a twin structure with four traffic lanes each. Its structure is designed as a cable-stayed bridge with concrete towers and composite...

Construction of the Clark Cable-Stayed Bridge at Alton, Illinois
The Clark Cable-Stayed Bridge crosses the Mississippi River at Alton, Illinois. The successful bid by McCarthy Bros/Clark Bridge JV was for the steel alternative. The bridge design included...

Damping Systems for Controlling Wind Induced Motions of Structures
This paper presents the state-of-the-art in damping systems for controlling wind induced motion of structures and their applications in the U.S. and Japan. Both passive and active systems...

Wind Studies of the Owensboro Bridge, Kentucky
Wind tunnel studies on the Owensboro Bridge are described in this paper, including 1:50 scale sectional model tests and 1:160 scale aeroelastic model tests. Comparisons are presented and...

Synthetic Wind for Investigations in Time-Domain
Buffeting investigations of large bridges carried out in time-domain permit modelling of the non-linearity of the system and wind force. Correct simulation of the natural wind plays a...

Reliability of Light-Gage Metal Joist Hangers
Limit state design equations are formulated to assess the reliability of light-gage metal joist hangers using the results of experimental studies. The design equations are calibrated against...

Timber Pile Length Determination Using a Nondestructive Technique
Determining timber pile length is critical when evaluating the potential effects of scour and for determining pile capacity. Unfortunately, records of timber pile lengths are typically...

Seismic Fragility Analysis of Sheahan Pumping Building
This paper presents a seismic fragility analysis of the Sheahan pumping building located in Memphis, Tennessee. In the analysis, seismic response is determined from the response spectrum...

Earthquake Barrier Technology: Sliding-Friction Energy Dissipation
The first project in America to use friction damping was approved by the City of Los Angeles for the retrofit of a 10-story concrete frame building, designed to resist a Maximum Credible...

Instrumentation and Testing of a Three Hinge Arch for Service Loads Increase
A three hinge arch railroad bridge was instrumented and tested to evaluate its condition and the required modification for increasing the service loads. Initially the structure was designed...

Seismic Response and Retrofitting of Non-Ductile Reinforced Concrete Bridges
The Interstate I5/I605 Separator in Los Angeles County was severely damaged during the October, 1 1987 Whittier Narrows Earthquake. This damage included non-ductile shear failure in the...

Aesthetic Considerations in the Design of a Stack Extension
The Connecticut D.E.P. mandated increase in height of the boiler stack at Backus Hospital in Norwich, CT presented many problems. Adding a new 45 foot vertical section atop the old brick...

Implementation of Passive Energy Dissipation Systems in the United States
Significant advances in the field of passive energy dissipation for improved structural seismic resistance have been made in recent years. Developments in research and analysis techniques...

Utilizing Visco-Elastic Dampers in the Seismic Retrofit of a Thirteen Story Steel Framed Building
A 13 story steel framed building in Santa Clara Country, California exhibited strong beating effects (torsional coupling) and prolonged building response as result of various seismic events....

Design and Field Performance of a Metal-Plate-Connected Wood Truss Bridge
This paper describes an on-going study on the design and performance attributes of an experimental wood-truss bridge. This is believed to be the first roadway bridge application of metal-plate-connected...

Acoustic Emission Monitoring of Steel Bridges
Global nondestructive monitoring techniques are of great significance for rapid monitoring of bridges. One promising technique involves monitoring the microseismic events (Acoustic Emissions,...

Long-Term Monitoring of Civil Structures using Smart Structures Techniques
A smart monitoring program for a hybrid concrete-steel building in Washington, D.C. has been developed. The building is currently being instrumented with a variety of strain and corrosion...

 

 

 

 

Return to search