High-Strength Concrete Columns: State of the Knowledge
This paper consists of reported information divided into two general categories, performance of High-Strength Concrete (HSC) columns under concentric loads, and combined axial and bending...
Progress in Reinforced Concrete Column Design
This paper reviews some of the design procedures used for both braced and unbraced frames constructed in reinforced concrete. The discussion refers to the problems of material and geometric...
Continuity in Precast Prestressed Concrete Girder Bridges
An experimental study conducted to evaluate the behavior of pretensioned bridge members made continuous with a cast-in-place concrete slab and diaphragm is summarized. In this study, the...
Harmonization of Reliability-Based Timber Engineering Codes and Standards
An overview of activities related to harmonization of reliability-based timber design codes and standards is presented. The overview is based on information generated through a NATO Advanced...
Use of Composite Timber-concrete Floors in Residential Buildings
Timber-concrete floors are widely used in the Gulf region for its resistance to hot and aggressive environment of the area. However, due to the fact that no shear connector is provided,...
The Canadian Approach in the Design of Wood Structures: Conversion to Limit States Design
During the early 70's, the National Building Code of Canada (NBCC) established the principle that structural design be carried out using the limit states design (LSD) method. The technical...
Strength Variability of Wood Formwork Members
Failure of concrete formwork is one of the main causes of concrete construction failures. Among the main causes of formwork failure is inadequate strength. Currently there is no published...
LRFD Provisions for Wood Bridges
A project to develop a load and resistance factor design (LRFD) edition of the American Association of State Highway and Transportation Officials (AASHTO) Standard Specifications for Highway...
Unified Code Provisions for Concrete Bridges
Provisions on limiting the flexural reinforcement adopted in the new AASHTO LRFD Specification for Bridge Design are summarized (1). They address minimum and maximum levels of reinforcement...
Guide for the Design of Prestressed Concrete Poles
With the aim of providing engineers with some basic tools and guidelines for the design of structures, the committee prepares code and policy changes, and to expand input of manufacturers...
ASCE GUIDE for Design of Guyed Transmission Structures
This paper describes the contents of a new ASCE guide for the selection and design of guyed electrical transmission structures. Guyed transmission structures present unique analysis and...
Design Guidelines for the Use of Debonded Strands
In this paper, presented are the flexural tests performed on beams containing debonded strands. Results show that debonded strands can be used reliably and safely, stipulating that the...
Development Length of Uncoated Prestressing Strand
The Federal Highway Administration is conducting ongoing research which investigates the development length of uncoated and epoxy coated prestressing strand in prestressed concrete members....
Mechanical Behavior of Dowels Embedded in Concrete
In this paper an experimental investigation on the behavior of dowels embedded in concrete is described. The dowel strength under monotonic forces with two different boundary conditions...
Construction of the Baytown Bridge, Houston
Connecting Baytown and LaPorte, the Baytown Bridge is a twin structure with four traffic lanes each. Its structure is designed as a cable-stayed bridge with concrete towers and composite...
Construction of the Clark Cable-Stayed Bridge at Alton, Illinois
The Clark Cable-Stayed Bridge crosses the Mississippi River at Alton, Illinois. The successful bid by McCarthy Bros/Clark Bridge JV was for the steel alternative. The bridge design included...
The Tatara Bridge - World's Longest Cable-Stayed Span
The Tatara Bridge now under construction has the main span length of 890m which will be the world's longest in cable-stayed bridges when completed. Except for certain lengths of prestressed...
Research and Development ? Why bother?
As the world becomes a true global marketplace, the ramifications of this change is felt in all aspects of business. Products and services from around the world are beginning to appear...
Cut and Cover Construction of the SSC Injector Tunnels
The injector system of the Superconducting Super Collider (SSC) constitutes the string of tunnels where protons are accelerated to near the speed of light and injected into the main collider...
High Strength Shotcrete and Concrete on the SSC Project
This paper addresses the technical aspects related to the use of high strength shotcrete and concrete on the Superconducting Super Collider (SSC) project. 7,000 psi shotcrete and 8,000...
Return to search