Modified Graphite Reference Electrodes
The primary aim of this research was to investigate the feasibility of developing an improved, more reproducible, reversible, and highly voltage invariant graphite reference half cell...

Design Implications for Concrete Pavements from LTPP Analyses
Among the original objectives of the Long-Term Pavement Performance (LTPP) study of the Strategic Highway Research Program (SHRP) were the evaluation of existing design methods for pavements,...

Durability of High Performance Concrete
The freeze-thaw durability and the resistance to chloride penetration of high performance concrete (HPC) developed for highway applications were investigated. This paper summarizes the...

An Evaluation of the Strategic Highway Research Project Packing Handbook
The objective of this paper is to present the use of the November 8, 1991 SHRP C-206 report entitled `Packing Handbook - A Guide to the Optimal Gradation of Concrete Aggregates'. The purpose...

Cathodic Protection for Protecting Prestressed Concrete
Due to the good effect of corrosion protection of reinforcing steel bars, even in concrete highly chloride contaminated, cathodic protection for concrete structure now carried out as a...

Application Cases of Slurry Seal in Japan
In Japan, slurry seal began to be used for repairing asphalt pavements at around 1963, mostly for repairs of prefectural and municipal roads. In recent years, however, it has rarely been...

Early Field Experience with SUPERPAVE
Specific pavement studies of newly constructed, reconstructed or rehabilitated (resurfaced) pavement sections were used to provide an estimate of the relative influence of key pavement...

Rehabilitation/Upgrading of Under-Rated or Deteriorating Single or Multi-Span Structures Using Corrugated Steel Pipe, Tunnel Liner Plate or Structural Plate
This paper cites advantages of the rehabilitation/upgrading of under-rated or deteriorating culverts or bridges using corrugated steel pipe, tunnel liner plate or structural plate. Among...

European Way of Standardization in the Field of Underground Pipe Renovation
European standardization is carried out within the framework of CEN (European Committee for Standardization). The development of standards for underground pipe renovation is taking place...

Television and Scanning Sonar in Seattle Metro's Siphons and Brick Sewers
Comprehensive and often costly investigations are required in order to identify performance deficiencies of the pipeline in sewer systems, particularly when sewers in excess of 48-inch...

Infrastructure Damage Modeling with GIS
This paper describes the use of a geographic information system to model damage to a municipal water distribution system. In a demonstration application detailed attribute data on components...

RCC: Rehab Results
Thirty dams have been modified with roller compacted concrete in order to provide additional spillway capacity and for safe overtopping of embankment dams. In the national dam safety inspection...

Plastic Potential
Some 220,000 tons of epoxy-coated steel has been used in the construction of bridge decks since 1987, but some have raised questions about its long-term durability. New materials for prestressing...

Detecting Leaks in Geomembranes
A field-tested leak-location survey, now commercially-available, can provide construction quality assurance or solve a leakage problem in lined landfills, impoundments or tanks. A liner...

Nondestructive Testing Role in Repair and Rehabilitation of Concrete Structures
Nondestructive testing (NDT) methods are increasingly being used to assess the condition of structural concrete. The paper discusses applications of NDT methods for forensic investigation...

Assessment and Repair of Fire-Damaged Concrete Structures
Concrete, even though it may be the most fire-resistant of all the major building materials, can be damaged by fire. Seldom does even a major fire cause total destruction, however, most...

Evaluation and Repair of Unbonded Post-Tensioned Concrete Structures
As with other forms of infrastructure, there is an ever increasing need to repair and strengthen unbonded post-tensioned concrete structures. Repairs may be necessitated for a variety...

Removal, Replacement and Rehabilitation of Concrete Slabs
The project involved existing one-way slabs experiencing severe corrosion damage. The slabs were removed and replaced while salvaging the concrete beams and frame components. Significant...

Bonded Concrete Overlays for Rehabilitation of Continuously Reinforced Concrete Pavement
As a result of the 1991 Intermodal Surface Transportation Efficiency Act (ISTEA), significant funding is now available for the rehabilitation of the nation's Interstate highway system....

Silica Fume Concrete: A Solution to Steel Reinforcement Corrosion in Concrete
This paper discusses the utilization of silica fume concrete admixture to prevent reinforcing steel corrosion. The mechanism of steel corrosion in salt impregnated concrete is described,...

 

 

 

 

Return to search