Seismic Codes:Preparing for the Unknown
Few eastern communities follow seismic codes because few communities view earthquakes as a risk. Although California-sized quakes have hit Charleston, St. Louis, they've done...

The Great Quake: On Site Reports
Written within two weeks of the Oct. 17, 1989 California earthquake, these comments cannot be considered definitive. But they do stress two points: 1) Earthquake codes do work. Buildings...

The Simulation of Variable Release Temperatures from the Rock Creek-Cresta Project Using the USFWS Instream Temperature Model
Pacific Gas and Electric Company (PGandE) operates the Rock Creek-Cresta Project on the North Fork Feather River (NFFR) for hydroelectric generation under authority of Federal Energy Regulatory...

Feasibility of Cold Water Releases from Lake Britton
The Pit River in Shasta County, California, is the site of the Pit 3, 4 and 5 Project, a major hydroelectric facility operated by the Pacific Gas and Electric Company (PGandE) under Federal...

Simulation of the Stanislaus Project: Performance of the U.S. Fish and Wildlife Service Instream Temperature Model on a Complex System
The primary objective of the study was to characterize the temperature regime of the MFSR Middle Fork Stanislaus River and determine the effect of alternate release flows on stream temperature...

Hydropower Simulation: An Overview
Numerous models have been developed for production costing and generation system expansion which include operation of hydropower in the system. These models rely on energy production and...

Reliable Operation of Hydro-Thermal Power Systems
The demonstrated model allows planners to account for both operating and shortage costs, subject to a constraint on the system failure rate. In addition, the optimal long-term operation...

A Short-Term Hydro Scheduler for Hydro-Thermal Power Systems
This paper presents HYDSIM (Hydro-electric Simulation), a new versatile computer model developed to simulate the hourly or daily operation of a large network of multi-purpose reservoirs...

Computerized Operation Models of Oroville Reservoir
Two monthly computer operational models, OROTHM1 and OROTHM2, were developed to provide more detailed operation and maintenance studies for the Oroville facilities. Currently another computer...

Frazil Ice Control Using Electromechanical Cibrators and Ice-Resistant Coatings
Two methods, using electromechanical vibrators and ice-resistant coatings, were studied in a small-scale test conducted at the U. S. Army Cold Regions Research and Engineering Laboratory...

Independent Turbine Testing and Research
The St. Anthony Falls Hydraulic Laboratory (SAFHL) is presently upgrading their Turbine Test Facility. Completion of the upgrade, including checkout tests, is scheduled for Fall 1987....

Large Low-Speed Generators with Skewed Supporting Parts
During the past decade, the demand for hydro-generators has been for increasingly high ratings, up to the present maximum of about 800 MVA. These low-speed machines have rotor diameters...

Monksville Dam: Design Evolution and Construction
This paper documents the application of experience gained at other RCC projects to the Monskville Dam. The evolution of the design and its translation to construction are presented together...

Saco Dam?South America's First RCC Dam
Because of cost and a lack of suitable embankment materials, Saco Dam at Nova Olinda in Paraiba, Brazil, was redesigned and built with lean roller compacted concrete (RCC). The structure...

Dynamic Maps for Seismic Risk Reduction and Effects of Soil Conditions
In order to perform useful vulnerability and risk evaluations, it is essential to have at one's disposal an automatic procedure of elaboration which provides answers in real time as soon...

Practical Implementation of Seismic Probabilistic Risk Assessment
Many techniques for seismic probabilistic risk assessment have been developed by university researchers over the last decade. This paper reports on a study being conducted to determine...

Bayesian Updating of Seismic Fragilities of Nuclear Power Plant Components
Seismic fragility is represented by a curve of the conditiional probability of failure as a function of the peak ground acceleration. Since there are many uncertainties in the model and...

Current Developments in Reinsulating/Waterproofing Underground Steam Mains in New York City
The objective of Con Edison's reinsulation project is to develop the materials and technology necessary to reinsulate those steam distribution mains having excessive thermal...

Seismic Counter-Measures for Buried Pipelines
This paper deals with the seismic counter-measures for mitigating hazards from earthquake damages to buried water and sewer pipelines. To achieve an overall program for the earthquake...

Arctic Coastal Processes and Slope Protection Design
Cold regions present special challenges for civil engineers. The papers in this book address arctic coastal processes and slope protection design. The first part of the book focuses on...

 

 

 

 

Return to search