Zooplankton Entrainment Evaluation in a Power Plant Station
The impact study on the Setubal thermal plant included an evaluation of the plant's effects on zooplankton in the outlet area. After entrainment in the cooling system there...

Hydraulic Fill Dam Made Earthquake Resistant
San Pablo Dam, near the San Andreas fault, constructed in 1919-21 by hydraulic fill methods, was found to be susceptible in places to liquefaction under seismic loading. The dam has been...

A Space Age Test Center
The Air Force's Aeropropulsion System Test Facility (ASTF) is the most expensive project the Air Force has ever built. Its massive heaters, coolers and compressors will treat...

An Instrumented Soil-Pipe System: Automated Data Acquisition and Management
A 16-in. natural gas pipeline near Racine, Wisconsin, had been in service for some 30 years. In 1982 road widening operations on a line parallel with the pipe resulted in a heavily trafficked...

Longitudinal Prestressed Piping for District Heating
The design of recently installed hot water district heating systems in the United States is based on similar systems developed in Europe. Longitudinal prestressing is used in the design...

Field Testing of 84-Inch-Diameter Plastic Pipe
During the summer of 1981, a research project was initiated to monitor strains and deformation in 84-inch diameter RPM (reinforced plastic mortar) pressure pipe. Three 20-foot (6. 1-m)...

Application of Water Budget to Seepage Loss Estimation
The seepage loss for the emergency cooling water spray pond has been calculated by performing a water balance study for the pond. A field test of the spray pond was performed to estimate...

Browns Ferry Nuclear Plant Thermal Compliance Monitoring Network: Utilization of Data
An automated water temperature monitoring network was designed to measure ambient and downstream heated river temperatures at Browns Ferry Nuclear Plant (BFN) in Wheeler Reservoir. The...

Applications of a Diffuser Performance Model at Browns Ferry Nuclear Plant
An unsteady flow model and a diffuser performance formulation were combined to more accurately determine plant-induced temperature effects. This model has been applied to several aspects...

Simulation of Far-Field Thermal Effects from Browns Ferry Nuclear Plant
A computer model was used to evaluate the far-field effects of revised thermal discharge limitations at the Tennessee Valley Authority's Browns Ferry Nuclear Plant (BFN)....

Integrated Hydrothermodynamic Study of Browns Ferry Nuclear Plant
The results of hydrothermodynamic analyses and computer models discussed in previous papers are combined to present an integrated study supporting a request for alternative thermal limits...

Small Canal Discharge Measurement by Thermal Dilution
Thermal dilution is a variation of the indicator dilution flow measurement technique, utilizing heat as the indicator. The measurement is accomplished by performing a heat balance within...

Biological Evaluation of Angled Screen Test Facility
The paper presents comparisons of model and prototype measurements as a means for evaluating the ability of a physical model to reproduce a geometrically complex prototype thermal intake...

Hydrothermal Model Study of Stratified Flow in a Power Plant Cooling Water Recycle/Intake Canal: Reynolds and Densimetric Froude Number Effects
During the winter of 1983-1984, the control of frazil ice at the trash tracks using pneumatic air guns was evaluated at Danskammer Point Generating Station. This paper presents a brief...

Frazil Ice Control Using Air Guns
The design of the J. H. Campbell, Unit 3, Cooling Water Intake in the late 1970's used some new ideas and concepts in response to a strong concern for fish protection at a...

Make-up and Blowdown of a Cooling Pond
A mathematical model was developed to simulate the operation of a recirculating cooling pond for a planned nuclear power plant in the Midwest. The objective of the pond operation is to...

Guideway and Conductor Rail Heating for a Winter Environment
The power and signal conducting rails are maintained using self-limiting heat trace cable in combination with an inherently protected rail. The cable's high inrush power along...

A Summary of the Seismic Qualification Utilities Group (SQUG) Program
In December of 1980, the Nuclear Regulatory Commission (NRC) initiated Unresolved Safety Issue (USI) A-46 to address the question of the seismic adequacy of equipment in 49 operating nuclear...

Seismic Design-Qualification of Non-Safety Related Items in Safety Related Envelope
This presentation pertains to Seismic Design-Qualification for those portions of structures, systems, or components in a Nuclear Plant whose continued function is not required but whose...

Strength of Soils in Terms of Effective Stress
The factors that determine soil strength, such as amount of confinement, density, particle size distribution, mineral friction, aging, particle crushing, and others, produce their effects...

 

 

 

 

Return to search