Site Load Testing of Full Scale Composite Concrete Floors
The paper presents the results of a load test carried out in 1982 on a continuous reinforced concrete slab with a permanent shuttering consisting of compressed straw (Stramit) or cement...
Ambient Vibration Response of a Long Span Bridge
Natural frequencies, mode shapes and damping characteristics for a long-span cable-stayed bridge were experimentally determined from a series of ambient vibration tests for both the cantilever...
Instrumentation Considerations for Nondestructive and Destructive Testing of Reinforced Concrete Slab Bridges
This paper examines the process of selection and calibration for instruments used in nondestructive and destructive field tests of a reinforced concrete slab bridge. Of great importance...
Remote Monitoring of a Stressed Timber Bridge Deck
The long term behavior of a CCA treated stressed timber deck bridge is being monitored, at present, using a remote data acquisition system. The bridge which is located in Gray, Maine was...
Monitoring Performance of Full Scale Structures
General Physics Services Corporation (GPSC) of Columbia, Maryland has developed a device for the remote long-term monitoring of full scale structures, such as highway bridges. This patented...
Full Scale Dynamic Monitoring of Highway Bridges
Sensitivity of identified modal properties by physical testing is critical for automated monitoring of bridge structural condition. It is investigated here considering flexure modes and...
In Situ Testing Performed at Jackson Lake Dam
Jackson Lake Dam was rehabilitated from 1986 to 1988 to increase seismic stability. Final foundation improvements consisted of dynamic compaction and mixed inplace soil cement columns....
Risk-Based Methodology for Seismic Rehabilitation of Earth Dams
A methodology for seismic risk analysis of earth dams is described. The procedure utilizes seismological and geotechnical inputs together with the associated uncertainties and provides...
Construction of CCM Overtopping Protection on Three Parkway Dams
Cellular concrete mat (CCM) systems have been installed as overtopping protection on three small embankment dams along the Blue Ridge Parkway. Based on field tests by others and on the...
Bond Stress Test on Rock Anchor in Clayey Siltstone
Seventy five rock anchors with design loads of 556 to 2040 kips were required for the 1000-foot long, 125-foot high, concrete gravity, Lake Lynn Dam to comply with current FERC engineering...
Improving Seismic Safety of Dams in California
A search of the dam files at California's Division of Safety of Dams has revealed that at least 94 dams have been improved for seismic stability. The results of the search are tabulated...
Development and Evaluation of Remediation Strategies by Deformation Analysis
Deformation analysis is providing guidance for the most efficient and economical seismic remedial treatments for Mormon Island Auxiliary and Sardis dams. The computer program TARA-3FL...
Seismic Stabilization of St. Joe State Park Tailings Dams
Tailings dams constructed by the `upstream' method are known to be seismically vulnerable, but field experience indicates that their seismic stability usually improves following termination...
Seismic Rehabilitation of Echo Lake Dam
Echo Lake Dam is an existing dam raising a natural lake in the Sierra Nevada in California, along the western edge of the Tahoe Basin. The dam was an embankment built with steep, hand...
Seismic Rehabilitation of Earth Dams
The purpose of this paper is to present methods available for engineered remediation of seismically deficient earth dams (not including tailings dams), review their strengths and weaknesses,...
Liquefaction Potential of Gravelly Soils in Dams
Gravelly soils are common components of embankment dams and their foundations. When such soils have been placed or deposited in a loose condition and are saturated, they are potentially...
Liquefaction Evaluation by Seismic Potential Procedure
Empirical procedures in common use for liquefaction evaluation employ information from a variety of sources in order to evaluate whether or not a site will undergo liquefaction. The information...
Software Applications for Monitoring Instrumentation Data
The initial program for reducing instrumentation data, used by the Geotechnical Branch of the Louisville District Corps of Engineers, was written in 1969. This program did not allow for...
Evaluation of Rehabilitation Needs for Hydraulic-Fill Dam
This paper describes the application of analytical methodologies developed for seismic stability analysis of dams in the western U.S. (particularly the Lower San Fernando Dam in Southern...
Testing and Evaluation of High Capacity, Multi-Strand Rock Anchors for Lake Lynn Dam
Seventy five rock anchors with design loads of 556 to 2040 kips were required for the 1000-foot long, 125-foot high, concrete gravity, Lake Lynn Dam to comply with current FERC engineering...
Return to search