A Reduced Order Model for the Seismic Analysis of Building-Soil Systems
A finite element based, reduced order, numerical model has been developed for the nonlinear analysis of building-soil systems. The reduced order system model employs an equivalent continuum...
Development of an Improved Rapid Seismic Analysis Procedure
New developments in computer capabilities and lessons learned from recent earthquakes have facilitated improvement of the Rapid Seismic Analysis Procedure (RSAP) currently specified in...
Inelastic Behavior of Noncompact Steel Bridge Girders
This paper highlights the results from one of several finite element studies of the inelastic moment-rotation behavior of continuous-span non-compact bridge girders at interior-pier locations....
Effects of Earthquake Intensities and Site Conditions on the Reliability of RC Frame Structures
This paper evaluates the effects of seismic zone factors and site coefficients on the seismic reliability of reinforced concrete frame structures. A nine-story intermediate moment-resisting...
A Prototype Expert System for Rapid Visual Screening of Seismically Hazardous Buildings in California
A rapid visual screening expert system, California Rapid Building Seismic Evaluation Expert, was developed to enable efficient and effective identification of seismically hazardous buildings...
Seismic Resistance of Steel Fiber Reinforced Concrete Beam-Column Joints
This paper discusses the advantages of using steel fibers in seismic resistant beam-column connections. First, the effects of fibers on the various aspects of behavior of concrete are...
Full-Scale Testing of Unreinforced Masonry Infill Frame Panels
This paper presents the results of the out-of-plane testing phase of the National Science Foundation Grant BCS 9102347. This phase of the program addresses the out-of-plane response to...
Out-of-plane and In-plane Testing of URM Infills
This paper summarizes the out-of-plane followed by in-plane quasi-static testing of two, full-scale Unreinforced Masonry (URM) Hollow Clay Tile (HCT) infills. The testing is part of a...
The Innovative Concept of Semi-rigid Composite Beam
This paper discusses invention and development of a new type of composite beam called 'Semi-rigid Composite Beam.' This new type of beam is expected to behave better than presently used...
Dynamic Response of Variable Height Retaining Walls
A full-scale dynamic test was conducted on a 140 ft long reinforced concrete retaining wall. The observed resonant configurations were similar to those of a cantilever plate and showed...
Analysis of the Seismic Records of a Suspension Bridge
A well-instrumented suspension bridge in Los Angeles, was shaken by the October 1, 1987 Whittier earthquake (ML = 5.9). This study addresses the...
Field Measurements of Wind-Induced Pressures on Roofs of Low Buildings
Full-scale measurements have been carried out on an experimental building, 3.3 m high, beside the football field at the Loyola campus of Concordia University. Wind-induced pressures have...
Site Load Testing of Full Scale Composite Concrete Floors
The paper presents the results of a load test carried out in 1982 on a continuous reinforced concrete slab with a permanent shuttering consisting of compressed straw (Stramit) or cement...
Ambient Vibration Response of a Long Span Bridge
Natural frequencies, mode shapes and damping characteristics for a long-span cable-stayed bridge were experimentally determined from a series of ambient vibration tests for both the cantilever...
Instrumentation Considerations for Nondestructive and Destructive Testing of Reinforced Concrete Slab Bridges
This paper examines the process of selection and calibration for instruments used in nondestructive and destructive field tests of a reinforced concrete slab bridge. Of great importance...
Remote Monitoring of a Stressed Timber Bridge Deck
The long term behavior of a CCA treated stressed timber deck bridge is being monitored, at present, using a remote data acquisition system. The bridge which is located in Gray, Maine was...
Monitoring Performance of Full Scale Structures
General Physics Services Corporation (GPSC) of Columbia, Maryland has developed a device for the remote long-term monitoring of full scale structures, such as highway bridges. This patented...
Full Scale Dynamic Monitoring of Highway Bridges
Sensitivity of identified modal properties by physical testing is critical for automated monitoring of bridge structural condition. It is investigated here considering flexure modes and...
In Situ Testing Performed at Jackson Lake Dam
Jackson Lake Dam was rehabilitated from 1986 to 1988 to increase seismic stability. Final foundation improvements consisted of dynamic compaction and mixed inplace soil cement columns....
Risk-Based Methodology for Seismic Rehabilitation of Earth Dams
A methodology for seismic risk analysis of earth dams is described. The procedure utilizes seismological and geotechnical inputs together with the associated uncertainties and provides...