Some Observations on Undrained Side Resistance of Drilled Shafts
A data base of 106 field load tests (65 in uplift and 41 in compression) is used to evaluate the undrained side resistance of drilled shaft foundations. The total stress or alpha (?) method...

New Design Method for Drilled Shafts from Common Soil and Rock Tests
A method is presented by which the compressive capacity and load-settlement characteristics of large drilled shafts can be computed from commonly executed soil and rock tests. The method...

Load Tests on Bored Friction Piles in Clay
For the first time in Boston, Massachusetts, U.S.A., uncased bored friction piles in clay were used to support a six-story residential structure over a 60- to 75-foot (1.83 to 22.9 m)...

Full Scale Caisson Load Test for the Milwaukee Center
Top-down procedures were proposed to construct four basement levels for a major high-rise building development in Milwaukee, Wisconsin. Drilled caisson foundations were the preferred means...

Drilled Shafts?A Database Approach
A database of 43 drilled shaft load tests of high quality has been developed to study parameters that affect the axial behavior of drilled shafts and methods of analysis to predict axial...

Interpretation of Load Tests on Drilled Shafts?Part 1: Axial Compression
Existing interpretation methods for axial compression load tests are reviewed critically, and a qualitative and quantitative comparison is made for selected methods. A simplified method,...

Interpretation of Load Tests on Drilled Shafts?Part 2: Axial Uplift
Existing interpretation methods for axial uplift load tests are reviewed critically, and a qualitative and quantitative comparison is made for selected methods. A new method, which fulfills...

Interpretation of Load Tests and Drilled Shafts?Part 3: Lateral and Moment
Existing interpretation methods for lateral and moment load tests are reviewed critically, and a qualitative and quantitative comparison is made for selected methods. A new method is proposed...

Nondestructive Testing of Deep Foundations with Sonic Methods
Nondestructive testing and evaluation (NDT&E) of deep foundations with three sonic methods is discussed. Case history investigations described include test records from drilled...

Geophysical and Nuclear Methods for Non-Destructive Evaluation of Caissons
Non-destructive testing techniques were used to confirm the concrete integrity on the caisson foundations for the 45-story Ohio Corporate Headquarters building in Cleveland, Ohio. The...

Bearing Capacity of Shallow Strip Foundation on Strong Clay Underlain by Weak Clay
Laboratory model test results for the ultimate bearing capacity of shallow strip foundations supported by a stiff clay layer underlain by a weaker clay layer have been presented. The model...

Rectangular Footing on Nonhomogeneous Elastic Half Space
The problem of a rectangular footing or a strip footing on a nonhomogeneous elastic half space is studied in this paper. The medium is assumed to be isotropic with a variable shear modulus...

Performance of a Large Ribbed Mat on Cohesive Soil
The performance of a 678-ft by 304-ft (207-m by 93-m) ribbed concrete mat was studied to provide improved soil input parameters for design. The mat was constructed on a low plasticity...

Bearing Capacity of Shallow Foundation on Granular Column in Weak Clay
Laboratory model tests results for the ultimate bearing capacity of shallow rectangular foundations supported by granular columns made in weak clay have been presented. In all cases, the...

Interpretation of Instrumented Driven Steel Pipe Piles
This paper presents the results of a series of studies on the behavior of driven close-ended steel pipe piles. Extensive field explorations and geotechnical analyses have been carried...

Issues in Evaluating Combined Repeated Loading of Deep Foundations
The capacity and load/displacement response of deep foundations subjected to combined modes of repeated loading can be significantly different from the response under single (axial or...

Pile-Drilled Caisson Combination for Foundation of High Rise Building
The analysis and evaluation of several alternatives for foundations of a high rise office building is presented, which resulted in the selection of a combination of high capacity piles...

Statistical Analyses of Drilled Shaft and Embedded Pole Models
In recent years a significant effort has been made by the Electric Power Research Institute (EPRI) to develop new design models, to collect and summarize existing load test data and to...

Cost Effective Pile Foundation Supports Fast Track Paper Mill
This paper decribes the generalized subsurface conditions, pile evaluation and load test program, pile and piling contractor selection, production pile installation, and quality assurance...

Analysis of Drilled Shafts in a Deep Fill
A deep fill of varying thickness will settle with time and will also exhibit a horizontal component of movement. Drilled shafts that are installed in the fill to support a structure must...

 

 

 

 