Design of Non-Pressure Very Flexible Plastic Pipe
There is considerable debate about the correct structural design procedure to be used for very flexible plastic pipe (VFP) - typically glass-fiber reinforced pipe (GRP), reinforced plastic...
Proportioning Reinforcement for Buried Concrete Pipe
The proportioning of reinforcement between inner and outer cages that is specified in ASTM Standard Specification C76 for concrete pipe in sewer and culvert applications is examined in...
Influence of Frost Action on the Load Exerted on Buried Pipe
When work was started on revising the Swedish code for concrete pipes at the end of the 70's, a research project was carried out to evaluate the risk of increased load due...
Reliability Evaluation of Water Distribution System Components
Reliability engineering concepts are substantially developed and have been routinely and successfully applied to the evaluation of electrical and mechanical components. However, these...
Pressurization and Depressurization in Pipe Flows
When a closed conduit drainage system is subjected to variable inflow rates, the change in flow regimes between free surface flow and pressurized flow may take place. A rising hydrograph...
Microcomputers in Hydraulics-Hydrology Education
Microcomputer software is utilized for pipe network analysis, unsteady flow in pipelines, watershed modeling, flood studies, reservoir operations, dam break analysis, and groundwater systems...
Overtopping of Small Dams?An Alternative for Dam Safety
A research effort was initiated in 1983 by the Bureau of Reclamation to gain insight in the development of cost-effective modifications to small embankment dams which would enable them...
Transients in Empty Pipes Subject to Rapid Filling
A mathematical model was developed to simulate the pipe filling process and the pipe forces based on incompressible water column theory. The method easily accomodates appropriate boundary...
Analysis of Resonance in Pressurized Piping Systems Via a Microcomputer
In this paper a digital simulation technique for the analysis of resonance is presented that is appropriate for microcomputer applications. The model utilizes the transfer matrix method...
Quick Stroking: A Fast and Accurate Algorithm for Time-Optimal Valve Closure Synthesis
In this paper, a fast, simple, yet effective technique for valve motion synthesis is developed. This technique called Quick Stroking is applied to a practical example problem, and it may...
Girth Weld Defect Tolerance Criteria
This paper describes the following criteria proposed for setting allowable defect sizes in girth welds: PD 6493:1980, 'Guidance on Some Methods for the Derivation of Acceptance...
Solutions in the Pipeline
Water and sewer agencies across the country are beginning to feel more comfortable about pipeline rehabilitation. Where once replacement was the ony alternative considered for aged, clogged...
You Need More Than a Plumber's Helper
Maintenance of subsurface drains may be the least understood and most neglected of all maintenance activities carried out by irrigation districts. Few irrigation districts have a maintenance...
Advances in Underground Pipeline Engineering
The field of underground pipeline engineering has undergone a rapid growth during the last two decades. The analysis, design, construction, operation, and maintenance of underground pipelines...
Accounting for Every Pipe
The Norfolk Sanitary Sewer Inventory and Appraisal System contains individual records for each of the 20,000 pipe segments in the Norfolk sewer system. The data, assembled from construction...
Tampa Does It with Mirrors
As one of the nation's fastest growing cities, Tampa needed far more public works dollars. But the traditional source, the real estate tax, can no longer be relied on so heavily,...
Pipe Laying Comes Out of the Trenches
Recent developments have shown that trenchless construction offers an effective and economically attractive alternative to conventional excavation. These findings are especially important...
Curved Sewers: Yes or No?
A study of curved sewer use in Southern California examines sewer design and maintenance of curved versus straight sewers. A telephone survey of personnel in design and maintenance of...
Repair�Don't Replace�Cracked Sewer Pipe
Approximately 0.5 mile (0.8 km) of 42 in. (1,07 m) diameter reinforced concrete was installed for a sanitary sewer project when the on site inspector discovered that numerous joints had...
The Sand Dam
Currently under construction is the 443 ft. high sand fill dam. Being erodible, pervious and liquefiable, sand would normally be considered as n unsuitable material to construct LaVueltosa...
Return to search