Allen-McColloch Pipeline Computer Based Control System
The Allen McColloch Pipeline (AMP) was designed to deliver 416 cfs of treated water from the Metropolitan Water District of Southern California's Diemer Water Treatment Plant...
Automatic Controls for Industrial Water System
An 8-mile pipeline and associated facilities along its route are controlled by a centralized system consisting of a master station and four remotes. Each site employs Westinghouse programmable...
Security of Unattended Pipeline Stations
The ultimate purpose of a security system is to maintain equipment and service in a normal operating condition or to restore the equipment and service to normal operating condition as...
Pipeline Hydraulic Transient and Leak Detection Analysis
Liquid and gas pipelines cannot be properly designed with consideration of steady flow analysis techniques alone due to the possibility of pipeline failure resulting from uncontrolled...
Design and Performance of Buried Fiberglass Pipes ? A New Perspective
The buried performance of fiberglass pipes was the subject of a comprehensive and multifaceted research program carried out in 1982 and 1983. Instrumentation, capable of accurately tracing...
Groundwater Basin Storage in Southern California
The feasibility of implementing a groundwater storage program in the Chino Groundwater Basin (Chino Basin) to increase the firm yield of the SWP (California State Water Project) is considered....
Selecting an Economical Water Main Rehab
Many miles of aging water mains exist with carrying capacities that are less than half of what they were when new. Engineers must, therefore, stretch every dollar to eliminate deposits...
Hydraulic Testing of a Large Make-Up Pipeline
A 37 mile pipeline which consists of sections of 114 inch, 96 inch and 66 inch pipes was constructed for delivering secondary sewage effluents for power plant makeup. During initial operations,...
Coping with High and Low Pressures of Transient Flow
Conditions exist in most long distance water pipelines, such that abnormal but inevitable occurrences will cause transient flow. Often the most crucial conditions for consideration by...
Hydraulic Analysis of Water Transmission Flowing Party Full
The hydraulic behavior of a transmission line that flows full along only part of its length is more difficult to analyze than a completely full line. Unsteady open-channel and closed-conduit...
Computer Aided Hydraulic Design of Pipelines
General purpose computer software packages are being used more frequently in the hydraulic design of pipeline systems. The areas where the use of such packages are advantageous over earlier...
Vacuum Assisted Pipelines Operation
In the process of upgrading the sewerage facilities for Lancaster, Pennsylvania, it was decided to combine two existing facilities into one new facility. This required the design of three...
Milwaukee Sewerage District Interplant Pipeline
The pipeline is intended to transfer solids between the Jones Island and South Shore treatment works a distance of approximately 12 miles (19. 3 km). The 4 conduit pipeline comprising...
Pipe Spillway Plunge Pool Design Equations
An equation is given to determine if scour holes will beach and widen excessively. For nonbeaching scour holes, dimensionless equations are given for the progression of scour with time...
Cavitation in Various Types of Shear Flow
Cavitation in turbulent shear flow depends on the intensity and spectral characteristics of the pressure fluctuations in a Lagrangian frame of reference as well as depending on the concentration...
A Quantitative Assessment of Surface Water Resources for Coal Slurry Pipelines Originating in Southwest Virginia
In view of the high streamflow variability, preliminary quantitative assessment was made of the capacity requirements and low-flow frequency characteristics of offstream reservoirs needed...
Hydropower Plant on an Irrigation Pipeline
A 940-kW hydroelectric plant was installed on a renovated irrigation pipeline at a Bishop, California ranch. On its way to the ranch, the falling water now generates an average of 4. 2...
Power from a Water Supply System: A Resource Which Can Be Tapped
There are numerous water supply systems from which hydroelectric power could be developed without impending the regular operational schedule. The basic principle of operation is not different...
Will Southern California Revert to a Desert?
The nearly 13 million people in Southern California - one-half of California's population - face the prospect of water shortages in the near future. These people depend on...
Design and Operation of Pipeline Control Systems
More and more of the time of the engineer involved in the design and construction of a pipeline project is devoted to problems relating to the control systems to operate and monitor the...
Return to search