Wind-Induced Vibrations of Tall Buildings Using Tuned Mass Damper
A Lagrange formulation is applied to tall buildings using tuned mass damper. The resulting equations of motion are analyzed using a frequency window method. The method reduces the computational...

Dynamic Inelastic Analysis of Tall Buildings
Members with undesirably early formed plastic hinges as well as excessive conservatism introduced in the preliminary design of tall buildings can be identified by the behavior state study...

Optimal Design of Building Structures Using the Predetermined Sections
A practical optimization algorithm for the member design of building structure is presented in this paper. The emphasis is particularly concentrated on the practical applicability of the...

A Shear Transfer Model for Floor-To-Wall Connections in Concrete Masonry Structures
Based upon experiments conducted at the Univ of California, San Diego (UCSD) on floor-to-wall connections in concrete masonry structures, a constitutive model was developed for the overall...

An Innovative Connection Detail for High-Rise Buildings
Composite columns consisting of hollow steel tubes filled with high strength concrete have been used in high rise building construction in the USA and Far East Asian countries. The focus...

Composite Beams and Joists
Composite beams and joists used as flexural members in multistory steel-frame buildings are considered. Research results have shown that present design values for headed shear studs, used...

Effects of Earthquake Intensities and Site Conditions on the Reliability of RC Frame Structures
This paper evaluates the effects of seismic zone factors and site coefficients on the seismic reliability of reinforced concrete frame structures. A nine-story intermediate moment-resisting...

Mapping Structural Damage to Monetary Damage
Earthquake damage estimation/prediction is still an area which requires expertise and judgment of the experts in the field. Making the predictions/estimates more accurate is an area of...

Flexural and Shear Behavior of Combined Concrete and Graphite Epoxy Beams
An experimental and analytical study of six graphite composite beams are presented. Four of the beams incorporated a reinforced concrete slab. The composite action and the effect of concrete...

Nonlinear Analysis of RC Beams Using High Performance FRC Matrices
The results of a nonlinear analysis model of reinforced concrete beams using a high performance fiber reinforced cement based matrix, particularly SIFCON (Slurry Infiltrated Fiber Concrete)...

Seismic Resistance of Steel Fiber Reinforced Concrete Beam-Column Joints
This paper discusses the advantages of using steel fibers in seismic resistant beam-column connections. First, the effects of fibers on the various aspects of behavior of concrete are...

Analysis and Design of SFRC Structural Elements
This paper presents and validates practical methods for flexural, shear and torsional analysis and design of fibrous reinforced concrete structural elements. The effects of both fiber...

Steel Fiber Reinforcement in Structural Application
Ribbon Technology Corporation's use of steel fiber reinforced concrete in the construction of their new manufacturing and office facility in Gahanna, Ohio. Cost savings are obtained by...

Strength, Behavior and Repair of Masonry Infills
Results of a series of experiments are presented on seismic performance of unreinforced masonry infill panels. The object of the investigation is to examine the loss of out-of-plane strength...

Built-Up Compression Members for Noval Structural Systems
This paper discusses built-up compression members used in novel structural systems for two high-rise buildings: InterFirst Plaza at Dallas Main Center and Columbus Center in New York....

QST Rolled Shapes, a New Generation of HSLA Compression Members
With the development of the Quenching and Self-Tempering (QST) process by the Luxembourg steelmaker ARBED S.A., a new generation of High Strength Low Alloy (HSLA) rolled shapes has become...

Creep and Shrinkage of Composite Columns in Tall Buildings
The simultaneous presence of steel and composite columns in tall buildings is a common occurrence. The axial shortening characteristics of composite columns are influenced by creep and...

Performance and Serviceability of Composite Floors
Concrete slabs on steel deck are the most common type of floor system in use today. This system of construction is particularly advantageous when ultimate strength design (LRFD) is used....

Dynamic Response of Variable Height Retaining Walls
A full-scale dynamic test was conducted on a 140 ft long reinforced concrete retaining wall. The observed resonant configurations were similar to those of a cantilever plate and showed...

Site Load Testing of Full Scale Composite Concrete Floors
The paper presents the results of a load test carried out in 1982 on a continuous reinforced concrete slab with a permanent shuttering consisting of compressed straw (Stramit) or cement...

 

 

 

 

Return to search