Composite Walling
This paper describes a study into a system of walling that comprises two skins of profiled steel sheeting infilled with concrete. During construction the steel sheeting acts as permanent...
The Definition of a Short Composite Column
A `short' column in composite construction is defined as one which can be designed for its cross-section strength alone without the need to consider stability effects. An extensive study...
Strength Deterioration Behavior of Concrete-Filled Steel Tubular Beam-Columns
Cantilever beam-columns of steel square hollow section with or without filled-concrete were tested under constant axial load and alternately repeated horizontal load to investigate the...
Force Transfer in Composite Columns
The force transfer from steel to concrete without mechanical transfer devices in composite columns at points of load introduction is studied. A mechanism of force transfer and the factors...
New Steel Beam to Composite Column Connection Detail
Composite columns consisting of hollow steel tubes filled with high strength concrete with compressive strength exceeding 10000 psi (69 MPa) are being used in high-rise buildings. Connecting...
Behavior of Unbonded Braces Restrained by Reinforced Concrete and FRP
A new composite steel brace called an unbonded brace (UB) is proposed to enhance the capacity of a steel brace to carry a compressive load of almost up to the yield strength of the steel...
Perfobond Rib Connectors for Composite Beams
In this paper, the influence of concrete strength, transverse reinforcement and concrete dowels on the capacity of perfobond rib shear connectors is examined. Perfobond rib connector is...
Steel Panel Encased R.C. Composite Shear Walls
In order to make clear the fundamental resisting mechanisms of composite shear walls, tests are carried out on the composite unit rigid frames with various infilled shear walls. Composite...
The Behaviour of Reinforced Concrete Beams Manufactured with Side Profile Sheets
The paper describes in qualitative terms the fundamental principles that control the behaviour of a completely new form of construction in which reinforced concrete beams are constructed...
Townsite Lateral-Stage 2 Belle Fourche Unit - Cheyenne Division Concrete: Pipe with Dumped Bedding and Embedment
In 1933, M. G. Spangler presented three bedding configurations and the concept of a bedding factor to relate the supporting strength of buried concrete pipe to the strength obtained in...
Flow Study of In-Service Sanitary Sewers Rehabilitated with Insitupipe
In an effort to define the flow characteristics of sanitary sewer segments rehabilitated with Insituform under normal in-service conditions, Insituform of North America, Inc. (currently...
PCCP Inspection and Remediation Methods
This paper presents detailed investigative procedures and methodology used to locate corroded Prestressed Concrete Cylinder Pipes (PCCP). It examines data collection by electronic devices,...
Joint Outfall H Relief Trunk Sewer System
The Joint Outfall 'H' Relief Trunk Sewer System consists of the construction of 11.3 kilometers (7 miles) of polyvinyl chloride lined reinforced concrete pipe varying in diameter from...
Concrete Pipe for Sanitary Sewers Corrosion Protection Update
Significant advances have been made in the last decade in the area of sanitary sewer design techniques. Some of the most important advances have been in the prediction and prevention of...
Caustic Spray for Sewer Crown Corrosion Control
A novel method to control sewer crown corrosion which involves spray application of a caustic solution to the sewer crown is described. Corrosion control using this concept is based on...
The Ivie Pipeline Delivering Water to West Texas
The Ivie Pipeline is a $76,000,000 - 156-mile long water pipeline being constructed in West Texas. This paper describes highlights of the planning, design, and construction phase....
Reinforced and Prestressed Concrete Pressure Pipe Diagnosis
Prestressed and reinforced concrete steel cylinder pipes are used for transmission mains, water intake lines, sewers force mains. Many collapses caused by the steel cylinder attack were...
Relocating a 54-Inch Diameter Force Main without Interrupting Wastewater Flow
The City of Tampa, Florida, was faced with the challenge of relocating three segments of an old 1372 mm (54-in.) diameter reinforced concrete pipe force main, totaling nearly a mile in...
Pipelines Crossing Highways and Railroads by Tunneling
When new pipeline construction requires the crossing of highways and railroads, a pipeline is generally installed in pipe or tunnel linear plate encasement which has been installed by...
Preventing Coating Delamination in Prestressed Concrete Pipe
This paper describes the results of experimental and analytical studies of mortar coating delamination of prestressed of concrete cylinder pipe. Coating delamination resulting from radial...
Return to search