Subway
Peachtree Center Station is the only mined transit station in the U.S. using reinforced native rock for permanent support. The station, serving some 34,000 patrons a day, is the largest...
Thermal Storage, Now and Future
Two-part article describes a 250 x 82 x 22 ft underground concrete tank that stores about 29,000 ton-hours of cooling effect for Yale University's medical school complex....
The San Diego Trolley
(
Chemical Spill Cleanup Named Project of the Year
A 1978 hazardous-waste spill in Michigan has been cleaned up so successfully that the American Consulting Engineers Council named it the 1982 project of the year. Here is how the railroad...
Compression Rings Support Deep Cut
The plans for building the Cuyahoga Valley Interceptor Lift Station in Cleveland, Ohio, called for 126 ft. (38.4 m) by 105 ft. (32 m) construction, some 80 ft. (24.4 m) below grade. Bracing...
Historic Preservation of Engineering Works
The preservation of historic industrial and transportation engineering works is examined. Preservation is reviewed in the context of history, and preservation through recording is explored....
Ugly Dump Site Transformed into Recreation Mega-Facility
The civil engineering project selected as the Outstanding Civil Engineering Achievement of 1981 is described. While other communities bemoan the use and loss of land to refuse disposal,...
Big New Radio Telescope Array Listens in on Space
The world's most powerful radio telescope is so sensitive that it can detect a small CB rig operating on a distant planet. The Very Large Array (VLA) Radio Telescope Facility...
Rocky Mountain Arsenal: Landmark Case of Groundwater Polluted by Chemicals
For more than 20 years, the Army's Rocky Mountain Arsenal near Denver has been dealing with groundwater pollution caused by chemical warfare agents and pesticides. The arsenal...
Design of Water Intake Structures for Fish Protection
This publication presents the results of a study on available technical information on the characteristics of water intake structures designed to eliminate or reduce damage to fish. Biological...
TVA's Pumped Storage Plant
TVA's Raccoon Mountain Plant is one of the U.S.'s largest with generating capacity of 1530 MW for 20 hours. The project, nominated for a 1980 OCEA, consists of...
Washington METRO: A People's Eye View
Much has been written about the technical aspects of this 101 mile, 86 station system. But as important in Washington, D.C. were the political aspects. Backed by Presidents; scrutinized...
First Line of Atlanta's New Transit System Opens
With lessons learned from San Francisco and Washington, D.C., Atlanta hopes to avoid some of the problems encountered by those cities in building and operating its new transit system....
Rx for Drought: Pumping Plant to the Rescue
Designed and built by the East Bay Municipal District, the pumping plant built last year at Middle River, Calif. was not unusual in design. What was unusual was the speed with which it...
Minnesota Interceptor Sewer Breaks New Ground
The Beltline Interceptor is a gravity interceptor sanitary sewer which has its outlet in St. Paul and its beginning in White Bear Lake. Major requirements called for a design which would...
Energy Utilization and Conservation in Wastewater Treatment
Rising costs of energy, and its limited supply in the United States, is requiring engineers to investigate the application of energy efficient processes for wastewater treatment. Energy...
Earth Retention by Drilled Reinforced Concrete Caissons
A hillside fill is stabilized by the construction of drilled reinforced concrete caissons. The fill supports a building which houses equipment important to a manufacturing process. Other...
Washington Metro Access Facilities
The 98 mi (158 km) Metro system will have 82 stations. There will be an off-street bus terminal at 54 of the stations with an average of six modified saw-tooth off-street bus bays at each...
Pipeline Design for Hydrocarbon Gases and Liquids
This report,
Sewage Treatment Plant Design
The purpose of this manual,