Seismic Rehabilitation of Earth Dams
The purpose of this paper is to present methods available for engineered remediation of seismically deficient earth dams (not including tailings dams), review their strengths and weaknesses,...
Liquefaction Evaluation by Seismic Potential Procedure
Empirical procedures in common use for liquefaction evaluation employ information from a variety of sources in order to evaluate whether or not a site will undergo liquefaction. The information...
Evaluation of Rehabilitation Needs for Hydraulic-Fill Dam
This paper describes the application of analytical methodologies developed for seismic stability analysis of dams in the western U.S. (particularly the Lower San Fernando Dam in Southern...
Economical Solution for Flood Overtopping Potential at Senator Wash Dam
A breach analysis of North Dike for overtopping with the crest modified to the lower elevation was required to ensure the breach discharge would be adequate to prevent overtopping of Senator...
Bureau of Reclamation Experience with Innovative Solutions to Increased Design Floods
Over the last several decades advances in the hydrologist's ability to estimate floods have resulted in increases to the design floods for many existing drainages. As with other dams throughout...
The Use of Post-Tensioned Anchorages on the Arch Portion of Stewart Mountain Dam, Arizona
Post-tensioned rock anchorages were selected by the Bureau of Reclamation (Reclamation) to stabilize Stewart Mountain Dam against potential seismic loadings. The use of such anchorages...
Seismic Stability Modification Requirements for Pineview Dam
Pineview Dam is located 8 km upstream from Ogden, Utah, and about 8 km from the Wasatch Fault Zone. Preconstruction information and construction records available at the outset of the...
U.S. Nuclear Regulatory Commission Staff Technical Position on Investigations to Identify Fault Displacement Hazards and Seismic Hazards at a Geologic Repository
This paper outlines the guidance provided to the U.S. Department of Energy by the Nuclear Regulatory Commission (NRC) staff in its Staff Technical Position (STP) on appropriate investigations...
Field Investigation of Mining-Induced Seismicity on Local Geohydrology
Hydraulic response of the rock mass due to earthquakes is one of the concerns in the assessment of the long-term performance of a repository. Studies performed by other researchers indicated...
Detachment Faults?Regulatory Implications for the Yucca Mountain Site
Site characterization investigations at the Yucca Mountain site, Nye County, Nevada consist of a combination of scientific data collection and analyses, and compliance with regulatory...
Seismic Reflection Profiling: Essential Geophysical Data for Yucca Mountain, Nevada
Yucca Mountain, Nevada, consists of a thick sequence of ashflow tuffs and lavas fractured into intact blocks with east-dipping strata, marginal broken zones characterized by dense faulting...
Optimum Operation of Recharge Basins
Mathematical models based on nonlinear programming are developed for operating recharge basin systems. The objective of these optimization models is to determine the operation policy that...
Dynamic Analysis and Design Considerations for High-Level Nuclear Waste Repositories
This proceedings,
The San Andreas Fault System, A Multimedia Earthquake Encyclopedia
The objective of this paper is to present the current efforts underway towards the development of the first multimedia earthquake encyclopedia. This is an attempt to use the treasury of...
Computer Methods Used on Seismic Retrofit Projects
Over a relatively short period of about twenty years, personal computers (PC's) have replaced slide rules in most engineering calculations. PC's are now staple equipment in every engineering...
Optimal Seismic Design of Structures
Structural design...
Geotechnical Practice in Dam Rehabilitation
This proceedings,
Structural Engineering in Natural Hazards Mitigation
This two-volume set of proceedings,
Lifelike Model
Data from about 400 structures in the San Francisco Bay Area were recorded during the 7.1 Richter-scale Loma Prieta quake. Among these structures was a 49-story office tower in downtown...
Colorado Dome
Innovative engineering and precise design helped engineers overcome a building's unique shape and difficult site to deliver the $71.5 million Jefferson County Government Center...