Input Programs for Engineering Applications
This paper discusses several input program types and the data structures associated with them. Two input programs were designed for KYPIPEF to demonstrate the use of files of records and...
Subsurface Drainage System for the Klamath Project
The U. S. Bureau of Reclamation's Klamath Project was authorized in 1905 for irrigation purposes. A subsurface drainage system was constructed in the public lands within the...
Detecting Underground Piping Leaks
Most leaks from underground liquid storage systems occur in the piping rather than the tank itself. The piping system is the most vulnerable component of the system, requiring great care...
Sewers Get a Breath of Fresh Air
Domestic sewage pump stations and treatment facilities have long been plagued by corrosion and odor problems caused by hydrogen sulfide. It is also extremely toxic. Sulfide production...
Sewer-Septic Tank Hybrid Promises Savings
Until recently the only options for sewage were the septic tank/leach field or conventional sewers. In some cases a hybrid of the two, called the septic tank/effluent drain, is less costly...
Earthquakes Will Not Damage This Bridge
A California pipeline bridge has been retrofitted with isolation bearings that damp earthquake shocks. The bridge over Southern California's Santa Ana River carries the Upper...
Solution to a Waterhammer Problem: A Case Study
Waterhammer is caused by a rapid change in the flow velocity of liquid in a pressurized pipeline. Therefore, the potential for waterhammer exists in almost every pressurized liquid piping...
Pipe-lining a Pipeline
This core prestressed concrete cylinder pipe is now lining the inside of a major water supply tunnel in Alaska. Occasionally found in rock tunnels, or buried pipelines, large diameter,...
Adfreeze Strength of Ice to Steel Pipe Piles as a Function of Temperature
A study was initiated to determine the adfreeze bond strength between steel pipe piles and freshwater ice as a function of temperature. Tests were conducted at an average strain rate of...
Alyeska Reroutes Trans-Alaska Pipeline at MP 200
This paper discusses the 1985 wintertime repair/reroute to the Trans Alaska Pipeline System (TAPS). The rerouted pipe was approximately 4000 feet long and cost approximately 27 million....
The Evolution of a Factory Insulated Piping System
This paper reviews the developments over the past fifteen years in a factory insulated high density polyethylene piping system that has become a standard for sewage and water piping systems...
Systems Model for Water Supply Following Earthquakes
The water supply for San Francisco is described with emphasis on the city's auxiliary water distribution network, which provides fire protection for the most heavily built-up...
The Effects of the 1985 Mexico City Earthquake on Underground Water & Sewer Pipelines
The 1985 Mexico City Earthquake left thousands dead and many thousands more without shelter. The visible damage was immense and terrible, and familiar to people around the world through...
Seismic Restraint of Hazardous Process Piping
The lack of appropriate guidelines for the design and installation of hazardous process piping in industrial facilities has created a potentially dangerous situation. Process piping carrying...
Response of Underground Pipelines to Dynamic Loads
The results of an investigation of the forced response of an underground pipeline due to dynamic loads are presented. The pipe is modelled as a linearly elastic shell element and the surrounding...
Port Expansion of Eastport, Maine
A recent pier expansion now allows Eastport to provide 40 feet of water at low tide. The pier expansion consists of a concrete-decked steel pipe pile-supported extension to an existing...
Rehabilitation of Wharf No. 8?Port of Houston
A routine inspection of wharves at the Turning Basin Terminal, uncovered evidence of extensive damage, including evidence that the 30-inch diameter steel pipe piles supporting Wharf No....
Predictions of Pile Shaft Capacity With the PLS Cell
In situ measurements of stresses and pore pressures on a model pile shaft, the Piezo-Lateral Stress (PLS) cell, are utilized to reconstruct the conditions of load tests involving two large...
Sulfide Corrosion and Control in the City of Modesto Primary Effluent Outfall (
The City of Modesto has a 60 inch diameter, 6- one-half mile long reinforced concrete pipeline conveying primary effluent from the primary treatment plant to the remote oxidation pond...
Hydrodynamics of Earth Fill Dam Breach Erosion
An analytical model is suggested in this paper. The model is based on the continuity equation of water mass within the reservoir, a broad-crested weir discharge formula and a velocity...
Return to search