Wind Loads on Low Rise Structures: A Survey
Because of the large investment, high rise buildings are usually tested in a wind tunnel to provide the best wind loading information possible. Since low rise structures each represent...

A Statistical Analysis of Wind Damage to Single-Family Dwellings Due to Hurricane Hugo
The claim files of 575 policy holders of the South Carolina Windstorm and Hail Underwriting Association were analyzed to determine the nature of wind damage to single-family dwellings...

Diaphragm Action of Cladding in Low-Rise Metal Buildings
An investigation of the contribution of cladding to the lateral stiffness of a metal building is presented in this paper. The diaphragm action of the cladding tends to redistribute the...

Uplift Resistance of Plywood and OSB Roof Sheathing
A test program to determine the resistance of plywood and OSB roof sheathing to uplift pressures created by wind flowing over a residential roof structure will provide valuable data to...

Behavior of Tall Frame Combining Rigid and Semi-Rigid Connections
In this paper, the applicability of the mixed use of rigid and semi-rigid connections in the tall frame is discussed. It is tried. for 4-bay 8-storey frame to be numerically analyzed for...

Bridging the Gap Between Architecture and Engineering
Building design is interdisciplinary by nature. Indeed, the collaboration of architect and structural engineer is critical to the success of building design projects. Yet with few exceptions...

Aesthetic Issues in Timber Bridges
The vocabulary of visual design and several generally accepted major principles of visual design are reviewed in order to provide a 'context' for case studies of award-winning timber bridges....

Implementation of Passive Energy Dissipation Systems in the United States
Significant advances in the field of passive energy dissipation for improved structural seismic resistance have been made in recent years. Developments in research and analysis techniques...

Utilizing Visco-Elastic Dampers in the Seismic Retrofit of a Thirteen Story Steel Framed Building
A 13 story steel framed building in Santa Clara Country, California exhibited strong beating effects (torsional coupling) and prolonged building response as result of various seismic events....

When are Loads Taught? A Case Study and National Trends.
Several years ago, structures faculty of the Department of Civil and Architectural Engineering at the University of Wyoming revised their structures courses to meet several new educational...

Where do the Arrows Come From? Evaluating Structural Loads
Two elements of an undergraduate's structural education that are not treated well in most textbooks are (1) the development of correct loads and (2) load modelling-that is, how the load...

Long-Term Monitoring of Civil Structures using Smart Structures Techniques
A smart monitoring program for a hybrid concrete-steel building in Washington, D.C. has been developed. The building is currently being instrumented with a variety of strain and corrosion...

Design and Construction of Post-Tensioned Concrete Floor Systems
This is a summary of the original full length paper which is available from the author. This paper assumes a basic technical knowledge of reinforced concrete design and prestressed concrete...

A Probabilistic Approach to the Response of Tall Buildings to Wind Loadings
Tall buildings constructed in recent years are light in weight, flexible and low in damping. This is the consequence of using lighter material with higher strength, and fewer interior...

Evaluation of Cast Iron Columns for Safety and Reliability
Cast iron columns exist in numerous vintage buildings. Alterations to these buildings often require analysis and modification of the structural system. This paper identifies codes that...

Messeturm Tower: Frankfurt, Germany
A 256 meter (840 feet)tall office tower, currently the tallest building in Europe, has been constructed in Frankfurt Germany. The 7- story structure with 85500 square meter (920,000 square...

The Slender Tower of 52-54 East End Avenue
The structural system for the 52-54 East End Avenue project is presented. The 40 story residential tower with as aspect ratio of 12: 1 is one of the most slender buildings constructed...

Gothic Structure and Design: Narbonne Cathedral
Viollet le Duc considered Narbonne Cathedral to be one of the best constructed Gothic buildings in France. The ambulatory piers are single courses of stone bonded into adjacent walls....

Floor to Wall Anchors in Historic Brick Buildings
The poster presentation at the Structures' Congress details a retrofit analysis performed on the Gilroy Historic Commercial Building, which was instrumented during the Loma Prieta Earthquake....

The Structural History of the Jacob Bachmann Tavern
The Jacob Bachmann Tavern is located in Easton, Pennsylvania. It is a collection of four interconnected buildings that have been constructed and modified over a period of 240 years. Structural...

 

 

 

 

Return to search