The Atlantic Palace?Part II The Application of Wind Tunnel/Force Balance Techniques
A relatively new approach for determining overall wind-induced loads on a structure is described. This force balance technique is economical and flexible, and able to provide predictions...

The Atlantic Palace: Part I Structural System Selection Based on Wind Tunnel Testing
The location of the structure in a coastal area susceptible to high winds, the irregular shape and height of the building and the desire for more accurate wind loading and acceleration...

A Stochastic Source Spectrum for Engineering Application
The solution of a point source (double couple) combined with K. Aki/A. S. Papageorgiou's stochastic source model is used to establish the power spectrum at the acceleration...

Structural Dynamics in Hurricanes and Tornadoes
The random fluctuations of wind gusts produce dynamic interaction with structures. The objectives of this paper are to identify distinguishing differences in hurricane and tornado winds...

It's Only Visual Inspection (Welding Inspection)
Unless specified otherwise in the Contract Documents, Visual Inspection will be performed on all fabrication/erection welding for projects that utilize the Specifications for the Design,...

Settlement of Light Buildings on Loose Sand
This paper reviews several cases of settlement of lightly loaded structures supported on granular soils. The concept of settlement ratio is presented. Measurements indicate that the settlement...

Settlement of a Reactor Containment on Sand
In this paper, predicted and observed settlements are presented for the reactor containment structure of the Beaver Valley Power Station - Unit 2, Shippingport, Pennsylvania. The Beaver...

Dynamic Response Correlation Using Simplified Models
A simplified model for building response which has a W. Ramberg-W. R. Osgood hysteresis is developed in a discrete sense. It is then used to evaluate the response of an instrumented, bearing...

Large Scale Testing Facility for the Evaluation of Structural Systems Under Critical Loads
The Charles Lee Powell Structural Systems Laboratory at the University of California, San Diego, provides, with a 50 ft. high reaction strong wall and a 120 multiplied by 50 ft. box girder...

Performance of an Earthquake Excited Roof Diaphragm
The objective of this paper is to study the earthquake performance of the roof diaphragm of the West Valley College gymnasium in Saratoga, California through a complete set of acceleration...

Experimental Studies, Structural Design and Full-Scale Measurements for the Columbia Seafirst Center
The Columbia Seafirst Center is a 76-story office tower located in downtown Seattle, Washington. It rises to a height of about 940 feet above ground and is the world's 10th...

Comparison of Predicted and Measured Dynamic Behavior of Allied Bank Plaza
Structural engineering aspects of a monitoring program to measure Allied Bank Plaza tower's dynamic response to wind are presented. In particular, field data developed during...

Damping in Tall Buildings: Its Variability and Treatment in Design
Increasingly, damping is being recognized as an important factor in the design of structures. It is at the same time a property which is relatively poorly defined, more acquired than engineered...

Design of Viscoelastic Dampers for Columbia Center Building
To reduce the dynamic response of a building with a given height and plan area to wind load, aside from inherent damping of the building, the designer has a few options available to him/her....

Performance of Viscoelastic Structural Dampers for the Columbia Center Building
Vibratory motion of structures such as buildings, bridges, and floors can be reduced by the use of viscoelastic (V. E. ) dampers. Such dampers transfer part of the vibratory energy of...

Monitoring a Bridge's Pulse
The Sunshine Skyway Bridge, which collapsed in 1980, is being replaced by the Florida Department of Transportation. The new Sunshine Skyway Bridge, which spans Tampa Bay between Bradenton...

The Public/Private Condo
A 20-story office building in Chicago was built on publicly owned land under a condominium arrangement that allowed a developer full ownership of air rights over and above the 100,000...

Complex Tower Meets Quake Code
A Los Angeles building consists of a triangular 23-story office tower stacked on top of an 11-story rectangular parking garage. The dual-shape is unique in seismically active southern...

Computer Cuts Tower Steel
Two computer programs developed by Lev Zetlin Assoc., New York City, revealed that some of the steel in what will be Philadelphia's tallest building, One Liberty Place, was...

Roof Membranes: New Systems, New Problems
Market trends in roof membranes are described; most important is the use of single-ply membranes of rubber or plastic in the past decade. A swing to modified bitumen membranes is predicted...

 

 

 

 

Return to search