Modeling 70,000 Feet of Interceptor for Aurora, CO
During preliminary design for the City of Aurora's Tollgate Creek Interceptor Sewer Improvements, the authors modeled over 70,000 linear feet of interceptor for both present...

A Comprehensive Algorithm for Network Calibration
An explicit calibration algorithm is proposed which provides the direct and rapid adjustment of the pipe roughness coefficients and junction node demands that exactly meet a specified...

UCD Drag Plate Lysimeter?Momentum and Mass Transfers
The second large (6.1 m dia., 0.97 m deep) lysimeter built at the University of California, Davis (UCD) was largely the brainchild of Dr. F.A. Brooks, the initial Project leader of a U.S....

Hydraulic Weighing Lysimeter Measurement Errors
A prototype size lysimeter was studied in the laboratory to determine accuracy and sources of error that might be caused by variable pillow contact area, temperature changes in various...

Computerized Data Acquisition for an Undergraduate Hydraulics Laboratory
Basic hydraulics principles and the operation of certain hydraulic systems can be effectively demonstrated with the aid of relatively inexpensive data acquisition and analyses systems....

Uncertainty Quantification in Water Distribution Parameter Estimation
Calibration for water distribution system model parameters is usually undertaken with a minimal amount of field measurements so additional pseudomeasurements are assumed. Both the actual...

Calibration of Beni-Mazar Movable Bed Model
A sand-bed model representing a reach of the Nile River was constructed to study alternative solutions to maintaining the navigation channel. Flume tests were carried out first to determine...

In-Situ Calibration of USGS Piezometer Installations
Among the few potentially liquefiable sites around the world that have been permanently instrumented with pore-pressure transducers and accelerometers, only the Wildlife Site in the Imperial...

Traffic Queue Detection Using Image-Processing
A method of queue/congestion detection is described using low cost image processing and computing hardware. It is capable of processing data from a length of roadway within a few seconds,...

Minimizing the Risk of Unsuccessful Modeling Exercises
Monte Carlo simulation techniques were employed to relate input parameter uncertainties to the characteristics of model output accuracy and reliability, and to the probability of successfully...

Calibrating the Chesapeake Bay Water Quality Model
A eutrophication model comprised of twenty-two state variables including three algal groups and multiple species of carbon, nitrogen, phosphorus, and silica is described. Equations governing...

Calibration of a Transport Model Using Halocarbons
A field study was conducted during April 1987 in which the concentrations of volatile halocarbon tracers, discharged from two existing outfalls, were measured throughout Boston Harbor...

Advection-Diffusion Calibration of Dissolved Oxygen
Modifications of J.J. Leendertse's water-quality model for improving calculations of dissolved oxygen concentrations in Jamaica Bay, New York, are discussed. Changes to the...

Data-Collection Program for Pamlico River Estuary Model Calibration and Validation
An investigation is being conducted to collect and interpret continuous records relating to the flow characteristics of the Pamlico River Estuary, North Carolina, and to calibrate and...

Neutron Physics Considerations in Moisture Probe Design
Neutron physics can be used to characterize most of the know behavior of neutrons in the soil. Scattering, absorption and slowing down are the principal processes affecting moisture probe...

Factors Affecting Neutron Gauge Calibration
Neutron gauge characteristics and soil chemistry affect gauge calibration. External factors also influence gauge calibration and should be considered in the calibration procedure. Gauge...

Access Tube Characteristics and Neutron Meter Calibration
Neutron meter calibration was found to be influenced by material type, thickness and size of access tube. Meter counts were decreased by an average of 15% for a 20% increase in tube diameter...

Relationship of Soil Type and Chemicals to the Calibration of Neutron Meters
Theory of neutron scattering and moderation in matter explains many of the characteristics of calibration curves of neutron moisture probes. Characteristics include effect of atomic species...

Field Calibration of Neutron Gauges: SCS Method
Field calibration of neutron gauges is easy and requires very little time under normal circumstances. Special soil sampling equipment is required that can be fabricated by most machine...

Practical Approaches Used in Neutron Meter Moisture Monitoring
This paper describes a practical, appropriate methodology for utilizing neutron meter soil moisture measurements to provide irrigation management information to farmers. A neutron meter...

 

 

 

 