U.S.-Japan Coordinated Program on Masonry Research
An overview of the U. S. -Japan Coordinated Program on Masonry Research is presented. The program consists of parallel efforts in Japan and the United States to develop design methods...

Sequential Earthquake Response of an Earth Dam
Sequential earthquake-response records of the well-instrumented Long Valley earth dam (Mammoth Lake area in California) are analyzed and engineering interpretations are made. The dam,...

Importance of Phasing of Strong Ground Motion in the Estimation of Structural Response
In this paper, the influence on Fourier phase spectrum of seismic source directivity due to rupture propagation along the earthquake source is investigated. The phasing is described using...

Evaluation of Building Response Recorded During the Morgan Hill Earthquake
On April 24, 1984, the Morgan Hill Earthquake (Richter magnitude 6. 2) occurred within approximately 15 km of IBM Corporation's computer-equipment manufacturing facility located...

Dynamics of Fender and Rack Systems for Docking Ferries
A dynamic analysis of a ferry fender and rack system is developed based on the conservation of energy principle and Newton's laws of motion. The dynamics of the interaction...

A Critical Look at Building Instrumentation in Earthquake Engineering
This paper discusses different issues and requirements existing in the area of building instrumentation. Strategies and types of equipment currently being used by the United States Geological...

Dynamic Testing of Structures Using the RESCUE Technique
This paper describes the most recent phase of an NSF supported program at SRI International to develop the technique of repeatable earth shaking by controlled underground expansion (RESCUE)...

Pseudo-Dynamic Testing of Structural Components
The pseudo-dynamic testing procedure is a simultaneous simulation and control process in which inertia and damping properties are simulated and flexibility properties are acquired from...

Seismic Tests of Friction Damped Steel Frames
This paper presents the results obtained from qualification tests of a new friction damping system, which has been proposed in order to improve the response of Moment Resisting Frames...

Nonlinear Behavior of Precast Concrete Shear Walls under Simulated Earthquake Loading
This paper presents experimental and analytical results on precast concrete shear walls under earthquake loading. It was observed in both small scale models tested and the computer analysis...

Hysteretic Behavior of Composite Diaphragms
Floor systems constructed with steel-deck-reinforced concrete are described. When used to resist lateral loads these systems are referred to as diaphragms. A description of a test arrangement,...

Precast Roofs for Blast Shelters
A shallow-buried reinforced concrete blast shelter has been constructed and dynamically tested at the U. S. Army Engineer Waterways Experiment Station (WES). Three thicknesses of precast...

Vibration Tests of Reservoir Structures Outlet Tower and Footbridge
This paper presents a field test procedure used in determining the dynamic properties of an outlet tower and footbridge for a major reservoir. Such factors as virtual water mass, soil-structure...

Dynamic Tests of LNG Storage Tanks for Earthquake Analysis of Liquid-Tank-Pile-Soil Interaction
This paper presents a field test procedure for determining the dynamic properties of large liquid natural gas (LNG) storage tanks under operating conditions. Two methods of vibratory excitation...

Floating Bridges in Short-Crested Random Seas
Four large concrete floating bridges located in Washington State have been the subject of extensive analytical modeling for dynamic response to storm waves. The dynamic analysis of the...

Significance of Nonlinear Modeling of R/C Columns to Seismic Response
Columns in reinforced concrete (R/C) structures exhibit complex hysteretic behavior during earthquakes. This can significantly influence predictions of overall response and damage distribution....

Earthquake Analysis of Liquid Storage Tanks
In the design of modern liquid storage tanks, it is of technical importance to examine their safety against earthquake damage. The methodologies used in design do not account for the major...

Refinements in Pseudo-Dynamic Test Procedures
One of the major concerns in seismic testing is whether the loading conditions imposed on a structure adequately represent those that might occur during a major earthquake. Response simulation...

Building Records from 1984 Morgan Hill Earthquake
The dynamic response of 23 structures instrumented by the California Strong Motion Instrumentation Program was recorded during the magnitude 6. 2 (ML) Morgan Hill earthquake of 24 April...

Use of Vibration Tests to Determine Lateral Load Paths in Medium Rise Buildings
A structural system identification procedure is described in which an initial analytical model of a building is modified until it predicts accurately the mode shapes and natural frequencies...

 

 

 

 

Return to search