Hysteretic Behavior of Composite Diaphragms
Floor systems constructed with steel-deck-reinforced concrete are described. When used to resist lateral loads these systems are referred to as diaphragms. A description of a test arrangement,...

Precast Roofs for Blast Shelters
A shallow-buried reinforced concrete blast shelter has been constructed and dynamically tested at the U. S. Army Engineer Waterways Experiment Station (WES). Three thicknesses of precast...

Vibration Tests of Reservoir Structures Outlet Tower and Footbridge
This paper presents a field test procedure used in determining the dynamic properties of an outlet tower and footbridge for a major reservoir. Such factors as virtual water mass, soil-structure...

Dynamic Tests of LNG Storage Tanks for Earthquake Analysis of Liquid-Tank-Pile-Soil Interaction
This paper presents a field test procedure for determining the dynamic properties of large liquid natural gas (LNG) storage tanks under operating conditions. Two methods of vibratory excitation...

Floating Bridges in Short-Crested Random Seas
Four large concrete floating bridges located in Washington State have been the subject of extensive analytical modeling for dynamic response to storm waves. The dynamic analysis of the...

Significance of Nonlinear Modeling of R/C Columns to Seismic Response
Columns in reinforced concrete (R/C) structures exhibit complex hysteretic behavior during earthquakes. This can significantly influence predictions of overall response and damage distribution....

Earthquake Analysis of Liquid Storage Tanks
In the design of modern liquid storage tanks, it is of technical importance to examine their safety against earthquake damage. The methodologies used in design do not account for the major...

Refinements in Pseudo-Dynamic Test Procedures
One of the major concerns in seismic testing is whether the loading conditions imposed on a structure adequately represent those that might occur during a major earthquake. Response simulation...

Building Records from 1984 Morgan Hill Earthquake
The dynamic response of 23 structures instrumented by the California Strong Motion Instrumentation Program was recorded during the magnitude 6. 2 (ML) Morgan Hill earthquake of 24 April...

Use of Vibration Tests to Determine Lateral Load Paths in Medium Rise Buildings
A structural system identification procedure is described in which an initial analytical model of a building is modified until it predicts accurately the mode shapes and natural frequencies...

Explosion Hazards to Urban Structures
Manufacture, storage and transportation of chemicals capable of exploding at energy levels comparable to TNT has increased in recent years. Land areas adjoining such facilities and transportation...

Some Experimental Results on the Dynamic Behaviour of a 40m Guyed Mast
This paper presents the first results and elaborations obtained from the tests of an experimental 40m tall guyed mast. The instruments installed to date are a cup anemometer on the mast...

Response of the San Juan Bautista 156/101 Bridge to the 1979 Coyote Lake Earthquake
Strong-motion accelerograms are used to examine the response of a multiple-span highway bridge to earthquake loading. Estimates of modal frequencies and damping values for the first two...

Seismic Behavior of Long-Span Cable-Stayed Bridges
Special features of the earthquake-response analysis of cable-stayed bridges, subjected to multiple-support excitation, are presented including a basis for calculation of seismic forces...

Seismic Response Analysis of Two Major Bridge Structures
The seismic response analyses of two major bridge structures have been conducted. In these two bridges, portions of the piles are either submerged in the water or free-standing within...

Performance of Existing Buildings: Results of Benchmark Structure Analyses Performed in U.S.-Japan Workshops
In response to the need for better understanding of current safety evaluation methodologies, three U. S. -Japan workshops have been conducted on the evaluation of the performance of existing...

Strengthening of a Multi-Story Building with Deflection Constraints
Occasionally the existing structural or nonstructural systems of a building being strengthened require the imposition of deflection constraints or limits in order to avoid an undesirable...

On Reliability-Based Structural Optimization for Earthquakes
Previous studies of reliability-based structural optimization have been extended in order to investigate the applicability of the linear statistical model in cases where random parameters...

Seismic Restraint of Hazardous Process Piping
The lack of appropriate guidelines for the design and installation of hazardous process piping in industrial facilities has created a potentially dangerous situation. Process piping carrying...

Three Phase Design for Wind Loads on Structures
The successful design of a structure requires three phases of work. These phases are: conceptual design, design development and design verification. The conceptual design is undertaken...

 

 

 

 

Return to search