Drilled Shaft Friction Evaluation via Pullout Tests
The history, development, and field test results of a small-scale 'pullout' test to assess the skin friction (fsu) for drilled shafts socketed in...

Verification of Deep Foundations by NDT Methods
Deep foundations are designed using static analysis techniques and the soil strength and structural integrity are then confirmed by static load tests. However, static tests are time consuming...

Piles for Marquette University Math Building
This paper presents a comparison of static pile capacity predictions using CPT cone resistance results with results of a test pile program and production pile driving. Pile capacity prediction...

3-D Deformation Analysis of Pile Groups During Wave Loading
Deformation predictions of pile group supporting one leg of Magnus platform were conducted using the 3-D nonlinear computer program SPLICE (Structure/Pile/Soil Interaction Analysis) and...

Evaluation and Monitoring of Pile Performance Using Dynamic Measurements in Supporting Offshore Structures
The installation of offshore platforms into deeper waters and new environments is accompanied by an increasing uncertainty in the structure response, foundation design and performance....

A Centrifuge and Analytical Study to Evaluate Suction Caissons for TLP Applications in the Gulf of Mexico
This paper documents the results of a combined centrifuge and analytical study to evaluate the behavior of steel suction caissons under loading and soil conditions typical of deepwater...

Behavior of Suction Piles in Sand
In the marine environment, use of suction pressure for the installation of sealed top piles (suction piles) is a promising alternative to driven pile foundations, particularly in deep...

Drilled Shaft Side Resistance in Clay Soil to Rock
An evaluation is made of available field load test data for the axial side clay soils to hard rocks. Conventional total stress interpretations by the alpha method are used to examine the...

Execution and Evaluation of High Capacity Caisson Load Tests in Glacial Deposits
As part of the Boston Harbor clean up project, the new 1,000 mgd Deer Island Sewerage treatment plant includes ten 240 feet high egg-shaped 'residuals' tanks. Contract documents called...

Bi-Directional Load Testing of Shafts to 6000 Tons
This paper describes the use of Osterberg cells (O-cells) to perform bi-directional load testing on full size production drilled shafts for a major bridge foundation near Owensboro, Kentucky....

Load Testing of Permanently Cased Drilled Shafts Founded in Hartford Shale
The axial and lateral load testing of three, 30 inch (76cm) diameter, permanently cased drilled shafts is analyzed herein. The prototype shafts were founded in (or on) Hartford Shale bedrock,...

Perimeter Load Transfer in Drilled Shafts in the Eagle Ford Formation
Results of six full-scale compression loading tests at four sites in the Dallas area are considered. Compressive strengths (qc) of the rock varied...

Side Resistance of Drilled Shafts in the Denver and Pierre Formations
Results of load tests on drilled shaft foundations in Upper Cretaceous shales are described and evaluated. Three load tests were conducted on shafts in the Denver Formation, in Denver,...

Behavior of Instrumented Model Piers in Manufactured Rock with a Soft Layer
A laboratory test apparatus has been used to study the side resistance of piers socketed into manufactured soft-rock masses. The results of four tests are reported, three of which included...

An Overview of Unsaturated Soil Behaviour

Transmitted Swelling Pressures on Retaining Structures
The main objectives of this paper are to describe a finite element model to simulate the lateral swelling behavior of expansive soils as a function of soil suction change in the soil domain...

Negative Skin Friction Due to Wetting of Unsaturated Soil
A steel building at a cement plant un Utah was originally supported by spread footings. Shallow wetting of the coarse granular soils supporting the footings resulted in over three inches...

A Laboratory Procedure for Partial-Wetting Collapse Determination
Partial wetting results in partial collapse, which is linked to the reduction in soil suction caused by wetting. The laboratory procedure presented in this paper represents a modification...

Osmotic Suction as a Valid Stress State Variable in Unsaturated Soil Mechanics
The hypothesis of the research being presented is that the osmotic suction of soil pore fluid is an independent, valid stress sate variable for unsaturated soils. A review of concepts...

Aspects of the Behavior of Clays on Drying
The drying behavior of compacted London Clay mixed with varying proportions of fine sand is examined, measuring the changes of sample volume, water content and suction. Particular attention...

 

 

 

 

Return to search