Behavior of Tall Frame Combining Rigid and Semi-Rigid Connections
In this paper, the applicability of the mixed use of rigid and semi-rigid connections in the tall frame is discussed. It is tried. for 4-bay 8-storey frame to be numerically analyzed for...

Seismic Analysis of Failure and Loss of Function of Water Pumping Facilities
Water company managers evaluating potential seismic damage effects on a pumping facility will require a reasonable estimate of the probable magnitude earthquake that has potential to disrupt...

Bulb-T and Glulam-FRP Beams for Timber Bridges
In this paper, we discusses the manufacturing, analysis, and testing of two glulam beam designers:(1) Southern pine bulb, and (2) yellow-poplar reinforced with pultruded fiber-reinforced...

Interpretation of Nondestructive Integrity Tests Using Artificial Neural Networks
A barrier to more frequent use of nondestructive integrity tests on cast-in-place foundations is the difficulty of interpreting the test results to identify the presence or absence of...

When are Loads Taught? A Case Study and National Trends.
Several years ago, structures faculty of the Department of Civil and Architectural Engineering at the University of Wyoming revised their structures courses to meet several new educational...

Experimental Measurements of Dynamic Loads Imposed by Moving Crowds
Dynamic forces generated by moving occupants were measured using an instrumented forces platform. Experiments were conducted for several sets of loads due to individuals and groups of...

Long-Term Monitoring of Civil Structures using Smart Structures Techniques
A smart monitoring program for a hybrid concrete-steel building in Washington, D.C. has been developed. The building is currently being instrumented with a variety of strain and corrosion...

Nonlinear Analysis of Prestressed Concrete Structures
This paper presents a finite element model for the nonlinear analysis of prestressed concrete structures. The model can be used to analyze pretensioned or posttensioned, bonded or unbonded...

Recent Advances in 3D Non-Linear FE-Analysis of R/C and P/C Beam Structures
A new simple modelling of interface problems in non-linear FE-analysis of reinforced concrete (R/C) and prestressed concrete (P/ C) structures is presented. It consists in taking account...

Prestressed Concrete Failures Due to Uplift
The paper presents some examples of prestressed concrete DOUBLE-TEE (DT) failures caused by hurricane Andrew. The DT's failures was mainly due to the negative moment created by uplift....

Reliability Analysis of Stiffened Panels
This paper presents a methodology to assess the reliability against collapse of structural members, as typified by the buckling collapse of stiffened deck panels in ship structures. This...

Cyclic Performance of Riveted Connections
As part of a larger experimental project on seismic performance of older steel frames, seven concrete-encased and unencased connections were tested. The specimens consisted of both riveted...

Seismic Retrofit of R/C Columns with Inadequate Lap Splices
This paper presents experimental results on the use of rectangular steel jackets to improve the seismic performance of rectangular steel jackets to improve the seismic performance of rectangular...

Steady-State Analysis of Buckle Propagation
A novel finite element technique for the analysis of buckle propagation in pipelines is presented. The propagation pressure, propagation profile, the state of stress, and deformation during...

Analysis of Unstiffened and Stiffened Tubular Members Under External Pressure and Structural Loads
This paper summarizes some important results concerning the ultimate capacity of stiffened and unstiffened tubes under combined loading. Such tubes are candidates for use in offshore structures...

Compressive Strength of Large Scale HSLA-80 Steel Cellular Sections of a Double Hull Ship Structure
An analytical and experimental large scale test program was conducted to investigate the instability failure modes of cellular double hull box sections. The main emphasis of the study...

Evaluation of Cast Iron Columns for Safety and Reliability
Cast iron columns exist in numerous vintage buildings. Alterations to these buildings often require analysis and modification of the structural system. This paper identifies codes that...

Design and Analysis of the 712 Fifth Avenue Structure
New York City's 712 Fifth Avenue is an extremely-slender concrete tube tower. This text addresses the structure's lateral structural system, wind analysis, computer model, thermal analysis...

Gothic Structure and Design: Narbonne Cathedral
Viollet le Duc considered Narbonne Cathedral to be one of the best constructed Gothic buildings in France. The ambulatory piers are single courses of stone bonded into adjacent walls....

Floor to Wall Anchors in Historic Brick Buildings
The poster presentation at the Structures' Congress details a retrofit analysis performed on the Gilroy Historic Commercial Building, which was instrumented during the Loma Prieta Earthquake....

 

 

 

 

Return to search