Transpiration by Douglas Fir Using Lysimeters
During the spring of 1971 a 28 m Douglas fir tree was installed in a weighing lysimeter. Some details of construction are presented. The weighing mechanism consisted of eleven lengths...

Water Table Lysimeter Data Interpretation
Lysimeters were used to estimate seasonal water use of wet meadows and phreatophytes in northern Utah, southeast Idaho and southwest Wyoming (1983-1990). Twelve water table lysimeters...

Alfalfa ET Measurements with Drainage Lysimeters
Drainage lysimeters were used to measure alfalfa evapotranspiration (ET) under a line-gradient sprinkler system in the high-elevation desert conditions of northwest New Mexico. The lysimeters...

Lysimeters Versus Buffer Areas Et and Agronomic Comparisons
Evapotranspiration (Et) from lysimeters may not represent Et of undisturbed, surrounding sites because of factors related to water, soils, plants, and even animal life. Et and agronomic...

Lysimetry for Evaporation and Transpiration Measurement
Large hydraulically weighed lysimeters were used to measure evapotranspiration (ET), evaporation (E), and transpiration (T). Weighing lysimeters for T measurements were covered to suppress...

Water Quality Sampling Under Preferential Flow Conditions
Shallow wells, porous cup samplers, and wick and gravity pan lysimeters were used to observe the movement of bromide applied to the surface of a grass covered field during a 23 day period....

Percolation Lysimeters for Water Quality Sampling
A field method to measure, year-around, the quantity and quality of leachate under irrigated crops has been developed. A specific objective was to evaluate percolation lysimeters as tools...

Lysimeters to Study Soil Water Movement and Crop Water Use Under High Water Table Conditions
A system of 6 drainage lysimeters was constructed to conduct studies of water use and water movement in 3 different soils influenced by high water tables. The lysimeters were equipped...

Drainage Lysimeters for High Water Table Citrus Studies
Forty drainage lysimeters were installed in 1988 to conduct water quality and consumptive use studies for citrus. The lysimeters were designed to simulate the high water table conditions...

Use of Lysimeters for Determining Characteristics of Pore Water
Lysimeters have been installed and used during the cleanup and stabilization of several former uranium processing sites in the western United States. In particular lysimeters have been...

High Saline Water-Table Effect on Wheat Irrigation
Hydraulic, weighing lysimeters were used for five years to measure the effect of high, saline water tables on irrigation requirement of wheat. Each year the wheat was grown with no water...

Comparation of Different Forms of Penman Equation
The research was carried out near Foggia (in Southern Italy) at 90 m above sea level and at 41? 27' N latitude, using two drainage lysimeters, filled with a silt clay soil...

Temporal Ion Balance Variation of an Irrigated Soil
The research was carried out in Southern Italy, from 1983 to 1988, using two gravity lysimeters irrigated with non saline water. The objective of this study was to test wether long-term...

Lysimeters: Data Acquisition and Analysis
Lysimeters provide the most direct method for measuring evapotranspiration (ET). For ten years we have used weighing lysimeters capable of a resolution equivalent to 0.02 mm of water....

Use of Lysimeters to Measure Fog Interception in Tussock Grassland New Zealand
Previous studies of the water balance of single Tussock plants in small non-weighing lysimeters over a range of elevations in east-central Otago province suggest that tussock grassland...

Representativeness of Floating Evapotranspirometers
In the first part of the paper, the design, the working principle and the field installation of floating evapotranspirometer are described with the data logging system which delivers continuous...

Installation and Operation of Large Drainage Lysimeters on Grapes
Six large (3.05 m ? 3.66 m ? 1.83 m) drainage lysimeters were installed in 1984 in the middle of a 1.2 ha trickle irrigated experimental vineyard. Each was planted to two V. vinifera grapevines....

Use of Lysimeters to Monitor a Sanitary Landfill
A vadose zone monitoring program has been developed using basin lysimeters to evaluate the environmental impacts of a sanitary waste landfill. Lysimeter systems, consisting of collection...

Relationship Between Lysimeter Area and Evapotranspiration (ET)
The lysimeter is an important instrument for measuring evapotranspiration (ET) of crops. It is widely used in the irrigation and drainage experimental stations in China. However, the areas...

Use of Lysimetric Measurements for Designing Major Irrigation Systems in the USSR
The bioclimatic method for calculation of crop water requirements has been widely used in the USSR in recent years. The author has analyzed the results of its application for designing...

 

 

 

 

Return to search