Recent Advances in Cone Penetrometer Measurements (Software and Hardware) and Its Application to Liquefaction Susceptibility
Some of the recent advances made in Cone Penetration Test (CPT) data acquisition system and real time processing of CPT data are presented. A key component of the new CPT data acquisition...
Ultimate Air Rights
The new 1 million sq ft office tower at 450 Lexington Ave. rises from available space between commuter railroad tracks, through the center of a renovated four-story post office and up...
GIS Plans Wastewater Future
When the Public Works Department began phase 3 construction on Albuquerque, N.M.'s current wastewater treatment plant in 1990, it was time to begin thinking about the next...
Engineering Women Into the Workplace
According to the U.S. Department of Labor, by the year 2000, only 15% of the work force will be white men; 64% will be women of mixed ethnic backgrounds. Clearly, statistics show that...
Civil Engineering Applications of Remote Sensing and Geographic Information Systems
This proceedings includes 41 of the papers presented at the Second National Specialty Conference on Civil Engineering Applications of Remote Sensing and Geographic Information Systems...
Computing in Civil Engineering and Symposium on Data Bases
This proceedings consists of the papers presented at the conference Computing in Civil Engineering and Symposium on Data Bases held in conjunction with A/E/C Systems '91 from May 6-8,...
Mechanics Computing in 1990's and Beyond
This proceedings,
Water Resources Planning and Management and Urban Water Resources
This proceedings,
Every Penny's Worth
Value engineering has been used in the construction industry since the 1960s, but highway projects have sometimes been thought of as too simple for VE studies. Now, with the increasing...
Caring for a Covered Bridge
Today the quaint Cornish-Windsor covered bridge (winner of this year's Outstanding Civil Engineering Merit Award) doesn't look much different than it did when...
Lifeline Earthquake Engineering at the Turn of the Century
The author considers it a singular honor to be the first recipient of the C. Martin Duke Award under the auspices of the Technical Council on Lifeline Earthquake Engineering (TCLEE) of...
Lifeline Earthquake Engineering in Japan: A State-of-the-Art
This is a subjective state-of-the-art report on the lifeline earthquake engineering in Japan. Beginning from the difference between civil engineering and building engineering in Japan,...
Lifeline Earthquake Engineering?A New Zealand Perspective
This paper outlines the application of earthquake engineering to New Zealand's lifelines, tracing the development of design practices in roading, bridging, power generation...
Seismic Practices for the Air Transportation System: Evolution and Needs
The seismic performance of air transportation systems is reviewed. The evolution of seismic design criteria and practices for major air transportation system elements is discussed. The...
Seismic Design Practices for Power Systems: Evolution, Evaluation, and Needs
The evolution of seismic design practices in electric power systems is reviewed. In California this evolution had led to many installation practices that are directed at improving the...
First Experience Concerning the Seismic Behaviour of an Electric Power System in Eastern North America
The November 25, 1988, Saguenay earthquake of magnitude MbLg=6.5 occurred in the province of Quebec, Canada....
Earthquake Evaluation of a Substation Network
The impact of the occurrence of a large, damaging earthquake on a regional electric power system is a function of the geographical distribution of strong shaking, the vulnerability of...
Two Decades of Communications Systems Seismic Protection Improvements
Telecommunications systems in North America have gone through significant technology changes in the past twenty years. The electro-mechanical switching equipment has been replaced by electronic...
Access Floor Response Spectra for Equipment Line-Ups in Telecommunications Central Offices
Modern telecommunications central offices very often utilize access floors to support equipment line-ups. An analytical study was carried out to study the seismic response of equipment...
Telecommunications Facilities Earthquake Readiness Since San Fernando
The vertical rack architecture of telecommunication offices showed some weaknesses during the San Fernando earthquake in 1970. Efforts have been made since then to improve performance...