Observation of Sediment Resuspension in Old Tampa Bay, Florida
Equipment and methodology have been developed to monitor sediment resuspension at two sites in Old Tampa Bay. Velocities are measured with electromagnetic current meters and suspended...

Estimation of Wave Power as an Energy Resource for Hawaii
One of the most important elements in determining the wave power available by means of a wave power extracting device is the amount of wave energy present at a given location during a...

Aussie Steel
The 50-story Chifley Square Building being built in Sydney will be the tallest Australian steel building. Scheduled for completion in June 1992 at a cost of $310 million, it will house...

Wind Bracing
This chapter discusses the structural design of the bridge with regards to wind forces....

Transmission Line Structure Loading
This paper outlines specific procedures for determining loads on transmission line structure systems that can be used in the reliability based design or assessment of components of these...

Sizing Techniques for Lateral Bracing
Techniques for determining the size of lateral bracing members in multi-story steel buildings are presented and discussed. Because the design of such bracing is usually controlled by deflection...

Steel Girt Design
Procedures are presented for the design of light gage cold formed girts and hot rolled girts. The effects of continuity, sag rods, and wall sheeting are discussed. Design procedures are...

Aerodynamic Improvements for Plate-Girder Bridges
This paper describes the application of wind tunnel tests on plate-girder cable-stayed bridges to ensure that the cross-section will not be susceptible to wind-induced oscillations. Information...

Inclined-Cable Aerodynamics
A series of wind tunnel tests have been conducted to clarify the fundamental mechanism of the vibration of the inclined cables of cable stayed bridges. The influence of the cable orientation...

Lateral Force Distribution in Manufactured Housing from Full-Scale Testing
The research focused on the behavior of two manufactured 14 ? 66 ft houses under simulated wind loads. Extensive instrumentation was employed to insure the collection of data that would...

Aerodynamic Modeling of Chimneys
The wake induced acrosswind behavior of circular cross-section structures, such as industrial chimney, has been studied for many years using wind tunnel models. Due to the relaxation of...

Mitigation of Wind-Induced Vibration of Tall Buildings
This paper summarizes a detailed study of the sensitivity of building acceleration to changes in structural stiffness, mass and damping and to the eccentricities in the centers of stiffness...

Aerodynamic Methods for Mitigating Wind-Induced Building Motions
Excessive wind-induced motions of tall buildings most frequently result from vortex shedding induced across-wind oscillations. This form of excitation is most pronounced for relatively...

Dynamic Response of a Building with Dual System
The paper presents the dynamic response of a 30-story building with dual system consisting of cross-bracing and beam-column moment resisting frames. Two types of beam-column connections,...

Tuned Liquid Damper and Its Application to Tower-Like Structures
A new kind of damper, Tuned Liquid Damper (TLD) relying upon motion of, shallow liquid in a rigid container for absorbing and dissipating the vibrations energy is explained. The performance...

Local Wind Pressures on Roofs
The paper reviews the results of the most recent research studies in the evaluation of wind pressure coefficients for the design of roof cladding elements. The effect of roof geometry...

Wind Effects on Loose-Laid Cladding Systems
Modern roofing systems for flat roofs frequently make use of rigid insulation boards, gravel and concrete pavers that are loose-laid on top of the waterproof membrane. The authors have...

Wind Performance of Asphalt Roofing Shingles
Pre-seal and post-seal wind resistance of asphalt roofing shingles is discussed. A test method for evaluating pre-seal wind damage is described. Wind tunnel testing results are presented...

Ballasted Single Ply Design Guide Development
A new roofing concept called ballasted single ply has now captured about 25% of the new and retrofit flat roof market. This concept relies on the use of ballast to provide the wind resistance...

Full-Scale Measurement on Chiba Port Tower
Chiba Port Tower is a tall tower, 125m high, with a rhombus shaped plan. All of the surfaces are covered with half mirror glass. On the top of the tower, a 'Tuned Mass Damper'...

 

 

 

 

Return to search