Fire Protection at the Grand Coulee Hydro Project
In the fall of 1980 a rupture of one of the Project's 525kV transmission cables occurred and created a fire. Power from three Third Powerplant 700MW units was interrupted,...

Experimental Investigation of the Cross Flow Turbine
A laboratory model of the Cross Flow Turbine was investigated in the Hydraulics laboratory of Colorado State University. Because of the successful use of this turbine in the developing...

An Integrated Site Controller-Network Monitoring System for Small Scale Hydroelectric Sites
Over the past decade more and more small scale hydroelectric power developers have faced the question of the economic feasibility of installing microprocessor based control systems for...

Influence of Surface Finish on Thrust Bearing Life
The original pivoted pad thrust bearing installed and fitted at the Holtwood Power Station in 1912 by A. Kingsbury has been operating continuously since that time without any difficulty....

Accelerated Life Testing of Generator Coils
This paper presents a step-by-step procedure for doing a 400 hour, 60 Hz, 90 degree C accelerated life test on generator coils. Test procedure is as follows: 1. Initial coil examination...

Fretting Corrosion on Large Split Thrust Bearing Runners
In the early fifties interfacial slip was measured on laboratory models. Design improvements, resulting from these tests, were incorporated into later machines. These improvements appreciably...

Upriver Dam Hydroelectric Project Rehabilitation After Failure, Part A: Failure Investigation and Lessons to be Learned
A lightning strike caused electrical failure at Spokane's two Upriver power plants, resulting in the river overtopping Project embankments, and causing nearly 11. 5 million...

Upriver Dam Hydroelectric Project Rehabilitation After Failure, Part B: Rehabilitation and Enhancement of Project Civil and Mechanical Facilities
A feasibility investigation of rehabilitation alternatives was conducted which identified several alternatives for repairing the damage and placing both powerhouses back on-line. These...

Behavior of Completed RCC Dams
Enough roller compacted concrete dams have been completed to allow an overall evaluation of this new approach to construction. Performance has been good. No operational restrictions have...

Monksville Dam: Design Evolution and Construction
This paper documents the application of experience gained at other RCC projects to the Monskville Dam. The evolution of the design and its translation to construction are presented together...

Saco Dam?South America's First RCC Dam
Because of cost and a lack of suitable embankment materials, Saco Dam at Nova Olinda in Paraiba, Brazil, was redesigned and built with lean roller compacted concrete (RCC). The structure...

Vibration Analysis Using a Parallel Lanczos Method
A parallel eigenvalue solution algorithm, based on the Lanczos method, has been developed, implemented on a Flexible Computer FLEX/32 multi-processor, and applied to an example structural...

Concurrent Nullspace Methods for Multibody Systems
This paper presents a new concurrent multiprocessing algorithm for simulating the dynamics of constrained multibody systems. The systems considered are quite general in nature; they may...

Structural Analysis and Parallel Computers
This paper discusses the implementation of a parallel program that performs a two dimensional rigid frame analysis on a NCUBE/7 hypercube multicomputer. The program was written in C and...

A Finite Element System for the CDC CYBER 205
This paper summarizes some of the special considerations required for finite element system development on the CDC CYBER 205. A means of constructing an efficient database is presented....

Finite Strip Method in a Parallel Computing Environment
The finite strip method has been used to model many systems in structural mechanics. The orthogonality of appropriately selected shape functions allows a continuous system to be effectively...

Flow Behavior of Kinked Strip Drains
Due to the often expressed concern over the axial deformation of strip drains and the resulting impact on flow rate, this study has been undertaken. A laboratory experiment has been constructed,...

Pull-Out Response of Geotextiles and Geogrids (Synthesis of Available Experimental Data)
During the past 15 years, there has been a considerable growth in the use of various materials to reinforce soils. The rapid development of geosynthetics and their increasing use in soil...

Finite Element Analyses of the St. Alban Test Embankments
Finite element analyses were performed of three embankments on sensitive clay that were constructed to failure at St. Alban, Quebec. One of the embankments was reinforced with flat-lying...

Laboratory Study of Geogrid Reinforced Soil Walls
The paper describes the construction and testing of three (3) large-scale geogrid reinforced soil retaining wall models. The models were 3 m high and were built in the RMC Retaining Wall...

 

 

 

 